4 wire installation
Q
Thread the 4=wire cable
through the strain relief
clamp.
Tighten the strain
relief clamp screws (2.5
Nm) so that the power
cord cannot be moved.
This will hold the power cord in
place and will make it easier to
correctly
install the terminal
screws.
®
Attach the power
cord ground
conductor
(green)
to the GROUND
.......
terminal.
Tighten
the screw (2.5
Nm) so that the
ground conductor
is held securely
in
place.
Attach the 2 power cord outer
conductors
(red and black,
either one can go left or right)
on the 2 terminals
labeled L.
Attach the remaining
power
cord conductor
(white) to the
terminal labeled
N.
Make sure the terminal
screws align
properly
with the terminal nuts to avoid
stripping
the threads.
Q
ighten all 3 terminal screws (3 Nm) so that each
of the wires is held securely in place.
are held securely in place to assure proper electrical
connection,
otherwise
a hazardous
condition could
result.
Q
heck the strain relief clamp to make sure that it
is tight and cannot be turned.
Q
eplace the cover on the terminal block and
fasten it in place.
Make sure the strain relief clamp is
outside the cover!
The appliance
is now ready to be plugged into a
properly
rated receptacle.