Advertisement

FOR YOUR SAFETY
If you smell gas:
1. Open windows and door.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult a
qualified installer, service agency or the gas
supplier.
If the refrigerator stops cooling - or - if
it emits an ammonia smell, immediate-
ly turn the refrigerator off and contact a
Service Center.
REVISION A
Form No. 3313935.000 09/16
INSTALLATION
&
OPERATING
INSTRUCTIONS
RM4605
RM4805
AES III

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM4605

  • Page 1 Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a RM4605 qualified installer, service agency or the gas RM4805 supplier. If the refrigerator stops cooling - or - if...
  • Page 2 INTRODUCTION SYMBOLS The following symbols are used throughout this manual: We are pleased that you have chosen this refrigerator This is the safety alert symbol. It and hope you will derive much satisfaction from using it. is used to alert you to personal The refrigerator is designed for installation into motor injury hazards.
  • Page 3: Table Of Contents

    CONTENTS OPERATING INSTRUCTIONS ______________ 4 CONTROL PANEL ......4 AES ........4 STARTING THE REFRIGERATOR .
  • Page 4: Operating Instructions

    OPERATING INSTRUCTIONS • When the vehicle’s engine is running, AES selects 12V operation and LEDs (A) and (D) are illuminated unless LP gas only opera- CONTROL PANEL tion has been selected manually. If neither mains nor a 12V battery supply are available: •...
  • Page 5: 230-240V Operation

    • Burner not igniting properly. • Burner fails to remain lit. In case the appliance fails to operate correctly, contact an authorized Dometic Service Center. DO NOT store explosive substances in the refrigerator, such as cigarette lighter gas, gasoline, ether or the like.
  • Page 6: Cleaning The Refrigerator

    4. Leave the cabinet and freezer door open. Defrost water runs from the drip tray through RM4605/RM4805 a plastic drain water hose to the outside of the vehicle. 5. When all the frost has melted - dry the interior of the refrigerator with a clean cloth and re- place the ice trays.
  • Page 7: Replacing The Bulb

    REPLACING THE BULB TROUBLESHOOTING IF THE REFRIGERATOR FAILS TO WORK To replace the bulb, follow these steps: 1. Remove the lamp cover. Push the lamp cover backwards. Before calling an authorized service technician: 2. Replace the old bulb with an appliance bulb of •...
  • Page 8: Service And Spare Parts

    Exhaust gases must be vented through the ventilation RM4805 1694 mm height wall to the outside of the vehicle. Dometic wall venting RM4605 1375 mm systems provide provision for venting the exhaust gases. RM4805 1534 mm Fig. 3 Consult your Dometic representative for further informa- tion.
  • Page 9: Technical Data

    CLEARANCES Minimum clearances (mm) to combustible materials RM4605 & RM4805 (Fig. 4 & Fig. 5) Side Bottom Rear The distance between the rearmost part of the refrigerator and the wall behind the refrigerator. Warm air deflecting plate Fig. 4 Fig. 5 RM4605 &...
  • Page 10 RM4605/RM4805 Electrical c o n n e c t i o n connection point 325.4 point Flue outlet pressure test 12V DC point Electrical connection connection point point...
  • Page 11: Building-In

    It is not a good practice to install the refrigerator so that • RM4605 & RM4805: The installer must block any space the vent openings are covered by the vehicle’s entrance between the counter, storage area or ceiling and top of door when this is set open.
  • Page 12: Drain Water Hose

    Remove the top decoration panel. Open Fig. 12 the door and gently push the tabs out of the Hole for drain water hose RM4605 hole in the hinge with a flat blade screw- RM4805 driver, (both sides), see Fig. 10.
  • Page 13 12 volt. the chassis for the return lead. The 12V supply must not be connected to a voltage con- RM4605 and RM4805: One terminal is marked “ 12V DC troller or similar device as the AES control system itself ”...
  • Page 14: Mounting Instructions

    REMOVING AND REPLACING THE Cross-sections The wires connected to this terminal must have a mini- SHELVES mum cross-section area of 1.5 mm D+ connection 1. Remove the shelf locks by inserting the tip of The connection D+ (alternator) has to be connected to the a flat bladed screwdriver into the slot of the corresponding outlet of the vehicles electrical system - ei- locks.
  • Page 15: Appendix A - Rear View Equipment

    APPENDIX A - REAR VIEW EQUIPMENT RM4605/RM4805 Heaters Reigniter Flue baffle Relay Screw for protection cover Power module (PC board) Protection cover 12V DC D + D + Inlet fitting Flexible cord Vehicle battery Burner jet connection 12V DC only...
  • Page 16: Appendix C - Working Instructions For The Gas Safety System

    APPENDIX C - WORKING INSTRUCTIONS FOR THE GAS SAFETY SYSTEM WORKING DIAGRAM Thermostat Spark Gas valve Flame detector device Lock out indication TW TS TS TWI TS TWI TS TECHNICAL SPECIFICATIONS Classification codes according to EN298 A-M-R-V-X-K Class of protection according to Low Voltage Directive IP-20 Waiting time / TW Safety time / TS...

This manual is also suitable for:

Rm4805

Table of Contents