Heat Pump Terminal Outputs - White Rodgers 1F92 Operating Instructions Manual

90 series premium universal universal multi-stage heat pump digital 5/2 day programmable
Table of Contents

Advertisement

HEAT PUMP TERMINAL OUTPUTS

HEAT PUMP TERMINAL OUTPUTS
HEAT PUMP TERMINAL OUTPUTS
HEAT PUMP TERMINAL OUTPUTS
HEAT PUMP TERMINAL OUTPUTS
Refer to equipment manufacturers'
instructions for specific system
wiring information.
You can configure the thermostat for
use with the following heat pump
system types:
HEAT PUMP TYPE 1. Single-
stage compressor system; gas or
electric backup.
HEAT PUMP TYPE 2. Multi-stage
or two-compressor system; gas or
electric backup.
HEAT PUMP TYPE 3. System
requiring separate signals for heat
(W1, W2) and cool (Y1); gas or
electric backup.
This thermostat is designed to
operate a single-transformer system.
If you have a two-transformer
system, cut and tape off one
transformer. If transformer safety
circuits are in only one of the
systems, remove the transformer of
the system with NO safety circuits. If
required, replace remaining trans-
former with a 75VA Class II
transformer. After disconnecting one
transformer, the two commons must
be jumpered together.
9
Installation
Use the terminal output information
on the next page to help you wire
the thermostat properly for your
heat pump system type. After
wiring, see CONFIGURATION
section for proper thermostat
configuration.