9. Carefully cut the blue wire going to the light switch.
Strip off 1/2-inch of insulation and connect this blue
wire to the blue wire from the light fixture (Figure
21) using a wire connector (supplied).
10. Carefully cut the white wire going to the
two-wire connector. Strip off 1/2-inch of insulation
and connect this white wire to the white wire from
the light fixture (Figure 21) using a wire connector
(supplied).
11. Engage the connector from the light adapter
plate with the connector from the motor
assembly (Figure 15). The two connectors are
keyed and color-coded and must be mated
correctly (color-to-color) before they can be
engaged. Make sure the connector latch closes
properly.
WARNING
!
To avoid possible fire or shock, make sure that the
electrical wires are not pinched between the light
adapter plate and the mounting plate.
TWO-WIRE
CONNECTOR
CUT WHITE
3
WIRE HERE
4
CONNECT TO WHITE
WIRE FROM LIGHT
FIXTURE
Figure 21
12. Position the light adapter plate over the light
fixture mounting plate. The adapter plate switches
must be located in the recessed portion of the
mounting plate (Figure 15). Align the holes in the
adapter plate with the holes in the mounting plate
and install four 5/32-32 x 5/16" Phillips flat head
screws (supplied) (Figure 22).
13. Cut the speed control switch pull chain to your
desired length (optional). Connect the wood
pendant (supplied) to the pull chain by sliding the
wood pendant (small hole first) onto the pull chain
(Figure 22). Then attach a chain coupling
(supplied) to the end of the chain and allow the
pendant to slide down over the coupling.
LIGHT
SWITCH
1
CUT BLUE WIRE
HERE
2
CONNECT TO BLUE WIRE
FROM LIGHT FIXTURE
9
ADAPTER PLATE
SWITCHES
WOOD PENDANT
CHAIN COUPLING
Figure 22

Using Your Ceiling Fan

1. Restore electrical power to the outlet box by turning
the electricity on at the main fuse box.
2. Check the operation of the fan by gently pulling on
the speed control pull chain switch (Figure 23). The
operating sequence is as follows:
THREE-SPEED
1st Pull—HIGH
2nd Pull—Medium
3rd Pull—Low
4th Pull—OFF
LIGHT CONTROL
SWITCH
REVERSING
SWITCH
Figure 23
3. If airflow is desired in opposite direction, turn your
fan off and wait for the blades to stop turning, then
slide the reversing switch to the opposite position,
and turn the fan on again. The fan blades will turn
in the opposite direction and reverse airflow.
4. Check the operation of the light fixture by gently
pulling on the light control pull chain switch.
5/32-32 x 5/16" PHILLIPS
FLAT HEAD SCREW (4)
LIGHT
ADAPTER
PLATE
SPEED CONTROL
SWITCH