How To Wire Your Ceiling Fan - Emerson CF654AW00 Owner's Manual

Wet location 52” ceiling fan
Table of Contents

Advertisement

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
WARNING
!
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground-
ed, contact a licensed electrician for advice, as it
must be grounded for safe operation.
1.Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this may
be a bare wire or wire with green colored insulation).
BLACK AND BLUE
FAN WIRES
GROUND
WIRE
WIRE
CONNECTORS (3)
GREEN WIRE
(GROUND)
FROM FAN
Figure 10
NOTE: If you are using an Emerson light fixture
with your fan, remove the three screws securing
the switch housing cover to the switch housing
and remove the cover. Remove the screw plug
from the bottom of the switch housing cover and
install the light in accordance with the light kit
Owner's Manual.
2.Connect the fan motor white wire to the supply
white (neutral) wire using a wire connector
(supplied) (Figure 10). Connect the fan motor black
wire and blue wire to the supply black (hot) wire
using a wire connector (supplied) (Figure 10). Your
fan is now wired to be turned on and off from the
fan switch. After connections have been made, turn
leads upward and carefully push leads into the out-
let box, with the white and green leads on one side
of the outlet box and the black and blue leads on
the other side of the outlet box.

How to Wire Your Ceiling Fan

NOTE: CEILING COVER
OMITTED FOR CLARITY.
WHITE SUPPLY
(NEUTRAL)
WHITE FAN
WIRE
BLACK SUPPLY
(HOT)
7
WARNING
!
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
3. Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.
4. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 11).
5. Secure the ceiling cover in place by sliding lockwash-
ers over the threaded studs and installing the two
knurled knobs (supplied). (Figure 11). Tighten the
knurled knobs securely until the ceiling cover fits
snugly against the ceiling and the hole in the ceiling
cover is clear of the downrod. Your fan is now wired to
be turned on and off from the fan switch.
THREADED STUD
KNURLED KNOB
Figure 11
WARNING
!
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
6.Cut the 3-speed switch pull chain to a desired length
(optional). Connect the wood pendant (supplied) to
the 3-speed switch pull chain by sliding the wooden
pendant (small hole first) onto the pull chain. Attach
the chain coupler to the end of the chain and allow the
wooden pendant to fall down over the coupling.
CEILING COVER
LOCKWASHERS (2)

Advertisement