EMC CLARiiON AX150 Series Data Book page 642

Emc support matrix
Table of Contents

Advertisement

No.
Host System
265
Sun Sun Blade Server Module: X6220, X6250, X8440
266
HPQ Proliant: DL320 (G5), DL360 (G5), DL385 (G2),
63
DL585 (G2), ML350 (G5)
, ML370 (G5)
63
(G4)
;
Hewlett Packard Proliant ML350: (G4), (G4p)
267
Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6800, 6850, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL320 (G5), DL360 (G5), DL385 (G2),
63
DL585 (G2), ML350 (G5)
, ML370 (G5)
63
(G4)
;
IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
268
Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
IBM: eServer 326m (Model 7969), xSeries x3655 (7985),
xSeries x3800/x260 (8866), xSeries x3850/x366 (8864);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
269
Fujitsu Siemens Primergy: RX220, RX600 S3, TX600 S3
270
HPQ Proliant DL585 (G2)
03/04/2009
Red Hat RHEL [x86_64]
Operating
System
Host Bus
Red Hat
PCI
RHEL
Express
[x86_64]
4.5
9, 56
AS/ES
Red Hat
PCI
63
, ML570
RHEL
Express,
[x86_64]
PCI−X
4.5
9, 56
AS/ES
Red Hat
PCI
RHEL
Express,
[x86_64]
PCI−X
4.5
9, 56
AS/ES
63
, ML570
Red Hat
PCI
RHEL
Express,
[x86_64]
PCI−X
4.5
9, 56
AS/ES
Red Hat
PCI
RHEL
Express,
[x86_64]
PCI−X
4.5
9, 56
AS/ES
Red Hat
PCI
RHEL
Express,
[x86_64]
PCI−X
4.5
9, 56
AS/ES
Host Bus Adapter
Topology
Sun:
FC−AL,
SG−XPCIE2FC−EB4−Z
FC−SW
3, 12, 31
(LPem11002)
,
SG−XPCIE2FC−QB4−Z
3, 82, 83
(QEM2462)
12, 15, 31
Emulex LP1050−E
FC−AL,
FC−SW
3, 12, 15,
Emulex LP1050−E
FC−AL,
31
FC−SW
3, 12,
Emulex LP1050Ex−E
FC−AL,
15, 31
FC−SW
3, 12,
Emulex LP1050Ex−E
FC−AL,
15, 31
FC−SW
3, 12, 14,
Emulex LP11000−E
FC−AL,
31
;
FC−SW
HPQ: A8002A/FC2142SR
3, 12, 14, 31
(LPe1150)
,
A8003A/FC2242SR
3, 12, 14, 31
(LPe11002)
,
AB429A/FC1143
3, 20, 67
(QLA2460)
,
AE311A/FC1142SR
3, 20, 67
(QLE2460)
,
AE369A/FC1243
3, 20, 67
(QLA2462)
;
3,
QLogic: QLA2460−E−SP
20, 67
3, 20,
, QLA2462−E−SP
67
639
CLARiiON AX150
Storage
External
Array
Boot
Comments
EMC
Y
CLARiiON
AX150
EMC
Y
CLARiiON
AX150
EMC
Y
CLARiiON
AX150
EMC
Y
CLARiiON
AX150
61
EMC
Y
CLARiiON
AX150
61
EMC
Y
CLARiiON
AX150
CLARiiON AX150

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents