READ AND UNDERSTAND
THESE INSTRUCTIONS
BEFORE INSTALLING
FlfiURE
INSTRUCTION
SHEET NO.
"his fixture is intended for installation
in accordance with the National Electrical Code and local regulations.
'o assure full compliance with local codes and regulations, check with your local electrical inspector before
nstallation.
To prevent electrical shock, turn off electricity at fuse box before proceeding.
IS:9196
Retain these instructions
for maintenance
reference.
0395
Page 1 of 1
T-BAR LIVE END
FOR USE WITH PROFILE, TRACK SYSTEMS
ONLY
WARNING:
TURN OFF POWER AT FUSE BOX BEFORE INSTALLING
ELECTRICAL
CONNECTOR
AND TRACK.
c DO NOT USE ELECTRICAL
CONNECTOR
AS A CONDUIT
SUPPORT.
INDEPENDENT
CONDUIT
SUPPORTS
(SUCH AS
CONDUIT
STRAPS)
MUST BE USED TO AllACH
THE CONDUIT
INSTALLATION
TO THE BUILDING
STRUCTURE.
OBSERVE POLARITY;
WHITE NEUTRAL WIRE MUST BE CONNECTED
TO THE TERMINAL
MARKED
"NE UT"
IN THE
ELECTRICAL
CONNECTOR.
USE 12 OR 14 GAUGE SOLID WIRE IN ELECTRICAL
CONNECTOR
ONLY.
NOTE: Special care must be taken when making the
hole in the mounting
surface
to prevent the hole from being visible
when the track is mounted.
The screws
on the ELECTRICAL
FITTING
may have to be cut to conceal
the mounting
hole.
A. INSTALLING
SURFACE
FEED CONNECTOR
1.
Point the POLARITY TAB away from the BEAD on the track.
.
.—
2. Insert SURFACE FEED CONNECTOR into track. Ensure CONTACT
BLADES insert into the TRACK CONDUCTOR GAPS.
4. Tighten
LOCKING SCREW.
!?
**OR
ELECTRICAL FITTING
B.
DIRECT POWER FEED.
1.
Remove BOTTOM COVER by removing
SCREW (retain).
2. Remove one K,O,
-
ELECTRICAL Fl~lNG
V'
)
(ByOTHEPS)
'
3. Attach the ELECTRICAL FITTING onto the METAL PLATE
4. Mount TRACK ASSEMBLY
to T-RUNNER using CLIPS 9188 or 9189.
/
(SOLD SEPARATELY),
/
'+
5. Pass Supply LEADS through
ELECTRICAL Fl~lNG
and
*
.
secure conduit to ELECTRICAL Fl~lNG.
6. Strip and form Supply LEADS to fit into
&>*
*
SURFACE FEED CONNECTOR, Fasten Supply
LEADS to SCREW TERMINALS;
NEUTRAL
(WHITE) LEAD to terminal
marked "NEUT"
GROUND LEAD to TERMINAL
marked "GND",
p~~~,
-OK,N~~~Ew
HOT (BLACK) LEAD to BRASS SCREW.
\
':.:'"'~-'--z:-z..
-,----
/ .
~~;-
-'::-
7, Fasten BOTTOM COVER to SURFACE FEED
\\=.-yy:
\
~~~~&
\c_-_—-—
–/
*
CONNECTOR using SCREW.
,F=~Q
'k'+
':
':
:
–
----~–-'''=l'
-'
J-
'a,
,,
/
BOTTOM COVER
'd>
~;:fRITy
r
TRACK —
Y
/
BEAD
-\
'~>
P
4
w
7/16"
,.
. ... . .. . ..!.5/
g>
STRIP
/iL/
~.._—
SUPPLY
WIRE
SCREW --
TWO WIRES MAY BE ATTACHED
TO ONE SCRE'AJ T ERMINAL
1.1
C>
I+
TC>I.
I
1:
1?
@
FALL RIVER, MASSACHUSETTS,
02720
MONTREAL,
QUEBEC,
CANADA
d
Need help?
Do you have a question about the T-BAR LIVE END and is the answer not in the manual?