Linear planar surface mount; wall/ceiling mounted t5 fluorescent ada compliant

Advertisement

Page 2 of 2
FP14U-FPA1
90°
50
60°
100
150
200
30°
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group • C0810
Brisa
DECORATIVE LUMINAIRE CAT. # FP14U-FPA1C
14W PHILIPS T-5 LAMPS. LUMEN RATING = 1200 LMS.
BALLAST/ ADVANCE ICN-2S28
Candlepower Summary
Angle Along 22.5.
45
67.5 Across.
Lumens
0
179
179
179
179
179
5
179
179
179
179
179
15
173
173
174
175
176
25
161
163
165
167
169
35
145
147
150
154
156
45
124
127
132
139
143
55
100
105
114
121
123
65
72
78
88
93
98
75
42
48
56
62
66
85
12
17
26
31
34
90
5
9
16
19
21
95
6
9
13
15
15
105
7
10
17
20
22
115
8
9
15
21
24
125
7
10
12
17
19
135
7
8
12
16
19
145
5
6
10
12
15
155
4
5
7
9
11
165
3
3
4
5
7
175
4
3
3
3
3
180
3
3
3
3
3
Linear Planar Surface Mount
Wall/Ceiling Mounted T5 Fluorescent ADA Compliant
Ceiling
80%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Output
0 .65 .65 .65 .65 .63 .63 .63 .63 .59 .59 .59 .55 .55 .55 .51 .51 .51 .50
9
1 .59 .57 .54 .52 .57 .55 .53 .50 .51 .49 .48 .48 .47 .45 .45 .44 .43 .41
25
2 .54 .49 .45 .42 .52 .48 .44 .41 .45 .42 .39 .42 .40 .37 .39 .37 .36 .34
38
3 .49 .43 .39 .35 .47 .42 .38 .34 .39 .36 .33 .37 .34 .32 .35 .32 .30 .29
47
4 .45 .38 .33 .30 .43 .37 .33 .29 .35 .31 .28 .33 .30 .27 .31 .28 .26 .24
51
5 .41 .34 .28 .25 .39 .33 .28 .24 .31 .27 .24 .29 .25 .23 .27 .24 .22 .20
51
6 .37 .30 .25 .21 .36 .29 .24 .21 .27 .23 .20 .26 .22 .20 .24 .21 .19 .18
43
7 .34 .27 .22 .19 .33 .26 .21 .18 .25 .20 .18 .23 .20 .17 .22 .19 .16 .15
29
14
8 .32 .24 .19 .16 .30 .23 .19 .16 .22 .18 .15 .21 .17 .15 .20 .17 .14 .13
9 .29 .22 .17 .14 .28 .21 .17 .13 .20 .16 .13 .19 .15 .13 .18 .15 .12 .11
7
10 .27 .20 .15 .12 .26 .19 .15 .12 .18 .14 .11 .17 .14 .11 .16 .13 .11 .10
8
7
Determined In Accordance With Current IES Published Procedures
6
5
3
2
1
Zonal Lumens and Percentages
0
Zone
Lumens
% Lamp
141
0-30
235
0-40
435
0-60
595
0-90
359
40-90
159
60-90
76
90-180
671
0-180
** Efficiency = 55.9%**
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
Job Information
  FP14LEC
Coefficients of Utilization
70%
50%
30%
Luminaire Input Watts = 32.0
Certified Test Report no. 3622FR
%Luminaire
Computed by LSI Program **TEST-LITE**
11.83
21.14
SC= 1.3
19.61
35.05
36.28
64.85
Prepared For:
49.60
88.66
Lightolier
29.99
53.61
Fall River, MA
13.32
23.81
6.35
11.34
55.94
100.00
Type:
10%
0

Advertisement

loading