Error Responses to Set_Attribute_Single – In certain conditions the inverter cannot
Set an attribute as the host has requested. For example, the host's data might be out-of-
range for the specified parameter. The inverter will return an error code, listed for the
specific condition in the table below.
Error Condition
The inverter is in Run Mode
A trip, undervoltage, or trip-retry exists
Software lock mode enabled
Executing auto-tuning
Value less than start frequency setting
Value less than lower frequency limit setting
Value more than upper frequency limit setting
Value more than maximum frequency setting
Out-of-range condition not listed above
NOTE: The Message Router Object (Class ID = 2 hex) is supported, but has no setting.
DeviceNet Object (Class ID = 3 hex)
Category
Attribute
Class
Revision
Instance 1
MAC ID
Baud rate
BOI
Bus OFF counter
Allocation information choice
byte
Master's MAC ID
Supported Services, DeviceNet Object
Service Name
Get_Attribute_Single
Set_Attribute_Single
Allocate_M/S_Connection_Set
Release_M/S_Connection_Set
SJ100DN Inverter
Type
Device state conflict
Invalid parameter
(check F_01, A_03,
A203, A_20–A_35,
A220, A_38, A_52,
A_61, A_62)
Invalid parameter
Access
ID
Data Type Initialization
Rule
1
Get
UINT
1
Get/Set
USINT
2
Get/Set
USINT
3
Get
BOOL
4
Get/Set
USINT
5
Get
BYTE
USINT
Code
Description
0Eh
10h
4Bh
4Ch
73
Type
Specific
code
error code
10h
00
01
02
04
20h
00
01
02
03
04
2
63
125k bits/sec.
0
0