Occurrence
timing
Detailed phenomenon
CR position
When turning on the power, the paper
Power on
feeding sequence is performed without
Anywhere
loading a paper in the paper loading
sequence.
When turning on the power, the CR unit
move to the home position correctly.
Operation
But, the paper feeding sequence is
Outside HP
performed without loading a paper in the
paper loading sequence.
Troubleshooting
Table 3-7. Check point for the paper jam error according to each phenomenon
Defective
unit/part name
1. Check if the Paper return plate operates correctly in the
ASF unit
1. Check if the Torsion spring 0.22 comes off on the both
Holder shaft unit
2. The HP/PE sensor is defective.
3. Check if the HP/PE sensor cable comes off.
4. Check if the HP/PE sensor cable is damaged.
5. Check if the HP/PE sensor cable is correctly placed on the
1. Check if the Torsion spring 0.22 for the HP sensor lever
Holder shaft unit *
2. Check if the HP/PE sensor cable is correctly placed on the
Unit Level Troubleshooting
Check point
paper loading sequence.
HP sensor lever and PE sensor lever.
Torsion sprig 0.22
LD shaft holder.
comes off.
LD shaft holder.
Revision A
Remedy
1. Reassemble the Tension spring 29.1 between
the ASF frame and the Paper return plate.
Torsion spring 29.1
1. Set the Torsion spring 0.22 to the suitable
position of the both levers.
2. Replace the Holder shaft unit with new one.
3. Replace the Holder shaft unit with new one.
4. Replace the Holder shaft unit with new one.
5. Replace the Holder shaft unit with new one.
1. Set the Torsion spring 0.22 to the suitable
position of the HP sensor lever.