Table 7-9. EEPROM Address Map (continued)
Address
Explanation
30H
Interface selection
01H : Auto
02H : Parallel
08H : USB
Others : Auto
31H
Interface time-out
0 to 255
(by second,
value of 0 means 10 seconds)
32H
I/F Speed
Bit7,6: Reserved
Bit5: Reserved
Bit4:
Bit3: ECP speed
Bit2:
Bit1: Compatibility speed
Bit0:
33H
Bi-D Adjustment 1
-36<=n<=+36(by 1/2880inch)
for Multi Shot Bk
34H
Bi-D Adjustment 2
-36<=n<=+36 (by 1/2880inch)
for 6pl VSD Bk
35H
Bi-D Adjustment 3
-36<=n<=+36 (by 1/2880inch)
for 4pl VSD Bk
36H
Bi-D Adjustment for
-36<=n<=+36 (by 1/2880inch)
Multi Shot (Cl)
37H
Bi-D Adjustment for
-36<=n<=+36 (by 1/2880inch)
6pl VSD (Cl)
38H
Bi-D Adjustment for
-36<=n<=+36 (by 1/2880inch)
4p lVSD (Cl)
39H
1stDot Position
-36<=n<=+36 (by 1/2880inch)
Adjustment
3AH
CL2 Counter KK
Appendix
QPIT
Factory
Setting
setting
setting
00H
00H
0AH
0AH
00H
00H
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
03H
Connector Summary
Address
Explanation
3BH
Total Timer CL
Counter
3CH
Printer For CSIC
3DH
CSIC1_InkName1;
3EH
CSIC2_InkName1;
3FH
Head Actuator Rank
+1<=n<=+32
ID for VhN
40H
Head Actuator Rank
+1<=n<=+37
ID for VhM
41H
Head Actuator Rank
+1<=n<=+34
ID for VhL
42H
Head Actuator Rank
+1<=n<=+34
ID for VhV
43H
Head Actuator Rank
+1<=n<=+40
ID for VhU
44H
Head Actuator Rank
+1<=n<=+34
ID for VhM2
45H
Head Actuator Rank
+1<=n<=+34
ID for VhB
46H
Head Actuator Rank
0<=n<=+6
ID for AR
47H
Head Actuator Rank
+30<=n<=+70
ID for IwB
48H
Head Actuator Rank
+30<=n<=+70
ID for IwC
49H
Head Actuator Rank
+30<=n<=+70
ID for IwM
4AH
Head Actuator Rank
+30<=n<=+70
ID for IwY
Revision A
QPIT
Factory
Setting
setting
setting
00H
00H
00H
9EH:
World
00H
00H
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)
00H
(*1)