System Options
For most installations the factory settings for the system will be
appropriate. To customize the system, enter programming mode via
telephone or keypad.
Use the programming worksheet supplied to log any system option
changes prior to entering it into the system.
For each of the following steps, enter the Master Password and enter
Programming Mode (if the unit is not already in that mode). Exit
Programming Mode when all programming is complete.
System Display Language
The factory default language is English. Three other languages can be
selected as the language for the user and programming displays.
✦ NOTE: This step cannot be performed remotely through the
telephone.
✦ NOTE: The system supports one display language at a time.
1. Press
2. Choose a language:
•
Enter 1 for English
•
Enter 2 for Spanish
•
Enter 3 for French
•
Enter 4 for Portuguese
3. Press
Keypad Lockout Count
The system counts the number of invalid Entry Codes entered at the
keypad. If the invalid entries exceeds the lockout count number, the
keypad is locked out for 90 seconds. The factory setting for the lockout
count is three. The lockout value can be from one to nine.
1. Press
2. Enter the number for the lockout count (1-9).
3. Press
Access Relay Activation Time
The factory setting will cause the access relay to activate for 4 seconds.
The activation time can be set from 4-99 seconds to accommodate
different types of access control devices.
1. Press
2. Enter the time (in seconds) for access relay to stay activated (04-99)
3. Press
STANDARD PROGRAMMING METHOD
SYSTEM DISPLAY LANGUAGE
LANG = SYSTEM DISPLAY LANGUAGE
KEYPAD LOCKOUT COUNT
COUNT = NUMBER (1-9) OF INCORRECT ENTRIES
THAT WILL CAUSE A 90 SECOND LOCKOUT
ACCESS RELAY ACTIVATION TIME
SECONDS = ACTIVATION TIME (04-99 SECONDS)
38#LANG#
1 = ENGLISH 2 = SPANISH
3 = FRENCH
4 = PORTUGUESE
FACTORY SETTING: ENGLISH
51#COUNT#
FACTORY SETTING: 3 TRIES
52#SECONDS#
FACTORY SETTING: 4 SECONDS
PPN 38
PPN 51
PPN 52