PRODUCT DATA (52P) (cont)
52PC performance and electrical data is the same as 52PE without electric heat.
MODEL
CAPACITY* (Btuh)
NUMBER
Cooling
52PE
007---3
7,200/ 7,100
207---3
7,200/ 7,100
307---3
7,200/ 7,100
009---3
9,100/ 9,000
209---3
9,100/ 9,000
309---3
9,100/ 9,000
012---3
12,100/12,000
212---3
12,100/12,000
312---3
12,100/12,000
512---3
12,100/12,000
015---3
15,000/14,700
215---3
15,000/14,700
315---3
15,000/14,700
515---3
15,000/14,700
MODEL
POWER
NUMBER
FACTOR
Horsepower
52PE
(%)
007---3
207---3
100
0.075
307---3
009---3
209---3
99
0.075
309---3
012---3
212---3
99
0.125
312---3
512---3
015---3
215---3
95
0.125
315---3
515---3
LEGEND
EER — Energy Efficiency Ratio
*Rated in accordance with ARI Standard 310-93.
†Electric resistance heater power and fan motor power.
**Fan motor indoor CFM (LO/HI) shown for 230-1-60 units.
PERFORMANCE AND ELECTRICAL DATA
MODEL 52PC AND PE (230/208-1-60)
HEATER
kW
Heating
7,800/ 6,400
2.3
11,600/ 9,700
3.4
7,800/ 6,400
2.3
11,600/ 9,700
3.4
7,800/ 6,400
2.3
11,600/ 9,700
3.4
17,000/13,600
5.0
7,800/ 6,400
2.3
11,600/ 9,700
3.4
17,000/13,600
5.0
FAN MOTOR
MAX.
FUSE
Full
Indoor
SIZE
Load
CFM
(Amps)
Amps
LO/HI**
15
0.44
220/260
15
20
15
0.44
220/260
15
20
15
15
0.75
270/350
20
30
15
15
0.75
250/320
20
30
UNIT NAMEPLATE VOLTAGE
OUTLET RATED VOLTS/AMPS
OUTLET BLADE CONFIGURATION
TIME DELAY FUSE OR HACR
CIRCUIT BREAKER (AMPS)
HEATER (KILOWATTS)
LEGEND
HACR
— Heating, Air Conditioning, and Refrigeration
NEMA
— National Electrical Manufacturers Association
*May be used for 15-amp applications if fused for 15 amps.
VOLTAGE
EER
RANGE
Cooling
(Volts)
12.7/12.7
2.7/2.9
12.7/12.7
2.7/2.9
12.7/12.7
2.7/2.9
11.7/11.9
3.0/3.1
11.7/11.9
3.0/3.1
11.7/11.9
3.0/3.1
11.1/10.7
4.8/5.3
187-253
11.1/10.7
4.8/5.3
11.1/10.7
4.8/5.3
11.1/10.7
4.8/5.3
9.8/ 9.8
6.4/7.1
9.8/ 9.8
6.4/7.1
9.8/ 9.8
6.4/7.1
9.8/ 9.8
6.4/7.1
MIN.
RECEP-
R-22
CIRCUIT
TACLE
CHARGE
AMPS
TYPE
(oz)
4.8
A
13.0
A
24
19.0
B
5.4
A
13.0
A
23
19.0
B
8.4
A
13.3
A
34
19.3
B
27.9
C
11.1
A
13.3
A
32
19.3
B
27.9
C
New York City Department of Buildings, Material and Equipment
Acceptance — MEA #242-04-E
RECEPTACLES AND FUSE TYPES
36
AMPS
WATTS
Heating†
Cooling
567/ 559
10.4/ 9.5
567/ 559
15.2/14.1
567/ 559
778/ 756
10.4/ 9.5
778/ 756
15.2/14.1
778/ 756
1090/1122
10.8/ 9.9
1090/1122
15.6/14.5
1090/1122
22.5/20.0
1090/1122
1531/1500
10.8/ 9.8
1531/1500
15.6/14.5
1531/1500
22.5/20.0
1531/1500
DEHUMIDIFI-
SENSIBLE
CATION
HEAT
(Pints/Hr)
FACTOR
1.5
0.78
2.4
0.73
3.4
0.71
4.8
0.66
230/208
250/15
250/20
A
B
15
20*
2.3
3.4
Heating
2393/1985
3493/2935
2393/1985
3493/2935
2470/2047
3570/2997
5170/4147
2470/2047
3570/2997
5170/4147
APPROX.
SHIP WT.
(lb)
125
125
140
150
250/30
C
30
5.0

Hide quick links: