8. Pneumatic connection

ATTENTION !
The faultless function of the pneumatic aggregates is only guaranteed
if the net pressure amounts to 8 to 10 bar.
The operating pressure of the sewing machine amounts to 6 bar.
1
2
3
6
4
8
2
10
4
Pneumatic connection package
Under the order number 0797 003031 a pneumatic connection
package for stands with compressed air maintenance unit is available.
It includes the following components:
Connecting hose, 5 m long Ø = 9 mm
Hose nozzles and hose clamps
Coupling socket and connector plug
Maintenance unit with manometer and pressure regulator
Connecting the compressed air maintenance unit
Fasten the compressed air maintenance unit 2 to the stand strut
with angle, screws and flap.
Connect the compressed air maintenance unit to the compressed
air supply with connecting hose 4 ( Ø = 9 mm) and hose coupling
R1/4".
Setting the operating pressure
The operating pressure is 6 bar.
It can be read off at manometer 3.
For adjusting the operating pressure raise and turn handle 1.
Increase the pressure = Turn twist handle 1 in clockwise direction
Reduce the pressure
= Turn twist handle 1 counter-clockwise