LP Gas

Tank Requirements
For plumbed-in LP installation, use a convertible regulator and set it
for LP gas.
Maximum line pressure for plumbed-in propane is 14" WC (3.5 kPa).
Minimum line pressure for propane is 11" WC.
The side burner unit must be used with the gas pressure regulator. The
regulator will control and maintain a uniform gas pressure in the mani-
fold. The burner orifices have been sized for the gas pressure delivered
by the regulator.
WARNING: Attempting to operate the side burner unit without the
gas regulator installed could cause an explosion and possible death.
Cylinder Specification
Any LP gas supply cylinder used with this side burner must be:
Constructed and marked in accordance with the
for LP-Gas Cylinders of the U.S. Department of Transportation
or the National Standard of Canada, CAN/CSA-B339, Cylin-
ders, Spheres and Tubes for Transportation of Dangerous
Goods; and Commission, as applicable.
Approximately 12 inches in diameter and 18 inches high.
The maximum fuel capacity is 20 lbs. of propane, or 5 gallons. Full cyl-
inder weight should be approximately 38 lbs. (43.7 lbs. nominal water
capacity.) Never fill the cylinder beyond 80% full.