Page 2
2. This device must accept any interference, including interfer- ence that may cause undesired operation. INTRODUCTION The PR-3000 receiver is compatible with all Dakota Alert 3000 Series transmit- ters (WMT-3000, WPT-3000, WHT-3000, UT-3000, and IR-3000). The PR-3000 is capable of receiving and storing alert signals from four zones.
When a signal is received, the zone will be displayed on the LCD screen and the receiver can be set to give an audible tone or a silent vibrate alert. Each zone can store up to 400 events with a time and date stamp or up to 999 events without a time and date stamp.
Page 4
Figure 2 THE PR-3000 (figure 2) 1. LCD display 2. (Side button) ON/OFF and Mode button 3. Left Button 4. Right Button 5. Charger plug 6. Reset button...
Page 5
LCD Display - Time/Date Mode (Figure 3) LCD Display Alert Mode 1. Time and Date mode (Figure 4) 2. Audible Tone icon 1. Last Channel received 3. Vibrate Alert icon 2. Number of alerts stored on 4. Lock icon the indicated channel 5.
Page 6
Alert Mode When the PR-3000 receives an alert, the LCD display changes to alert mode. The display will remain in alert mode, showing the most recent alert received until manually reseting to time/date mode. Push the right button to change from the alert mode to the time/date mode.
Page 7
Setting the Time and Date 1. Push the side and right button to enter the time/date setting screen in the programming mode. The hour digits will be flashing. 2. Push the right button to change the hour to the correct setting. (holding the right button down will scroll through the numbers quickly.) 3.
Page 8
Programming the vibrate alert From the audible tone setting screen, push the side button to access the vibrate alert programming screen. The vibrate alert icon will flash and there will be “ON” or “OFF” in the upper right section of the display. Use the right button to toggle between on and off.
Page 9
Locking the display Pushing the left and right buttons at the same time will lock the display in the time/date mode. The top of the display (figure 3) and no other screens can be viewed. Pushing the left and right buttons again will unlock the display.
Page 10
Clearing the alert log The alerts stored for a channel can be cleared through the alert log screen. Access the alert log, display the channel to be cleared, and push the side button. The text CLrE- COrd (clear record) will appear on the bottom of the display (figure 8).
WARRANTY Dakota Alert warrants this product to be free of defects in material and work- manship for a period of one year from the date of purchase. This warranty does not cover damage resulting from accident, abuse, act of God or im- proper operation.
Page 12
Dakota Alert, Inc. 109 W. Main St. Phone: (605) 356-2772 P0 Box 130 Fax: (605) 356-2584 Elk Point, SD 57025 Web: www.dakotaalert.com...
Need help?
Do you have a question about the PR-3000 and is the answer not in the manual?
Questions and answers