10
Operation

FUSE REPLACEMENT

FUSE/S
Figure 3
IF LIGHTS FAIL TO OPERATE, DISCONNECT POWER AT THE
SERVICE ENTRANCE. CHECK THE FUSE AND REPLACE IF
NECESSARY.
1 Remove grease filters.
2 Remove the electrical box support and open the fuse box.
3 Unscrew the cap from the fuse holder and remove the fuse.
4 Replace the fuse with the same size and amperage (5 x 20mm,
4 amp, 125 volt).
CAUTION
Use of a fuse greater than 4 amps may damage the transformer.
5 Reconnect power at the service entrance.