Gas Burners - Zanussi ZCG560G User Manual

Hide thumbs Also See for ZCG560G:
Table of Contents

Advertisement

Burner
Auxiliary
Semi-rapid

Gas burners

NORMAL
POWER
BURNER
kW
1,00
Auxiliary
1,00
burner
0,85
2,00
Semi-rapid
2,00
burner
1,70
3,00
Rapid burner
3,00
2,60
2,70
Oven
2,50
2,15
Gas Connection
Choose fixed connections or use a flexible pipe
in stainless steel in compliance with the regula-
tion in force. If you use flexible metallic pipes,
be careful they do not come in touch with mo-
bile parts or they are not squeezed.
When you install and connect the appli-
ance, obey the directives:
• SVGW- Gas principles G1: Gas installation
• EKAS- Form. 1942: Liquid gas directive, Part
2
• Cantonal instances regulations (e.g. fire safe-
ty regulators)
www.zanussi.com
Ø By-pass in 1/100
mm.
25
29
REDUCED
Type of
POWER
kW
Natural gas
0,35
0,35
Butane G30
0,31
Propane
Natural gas
0,43
0,43
Butane G30
0,40
Propane
Natural gas
0,72
0,72
Butane G30
0,63
Propane
0,90
Natural gas
0,90
Butane G30
0,78
Propane
Burner
Rapid
Oven
Pressure
gas
mbar
20
G20
50
50
G31
20
G20
50
50
G31
20
G20
50
50
G31
20
G20
50
50
G31
Flexible nonmetal pipes connection
If it is possible to easily and fully control the gas
connection, you can use a flexible pipe. You
must tightly attach the flexible pipe by clamps.
To install, use a pipe holder. Make sure that you
tightly attach the pipe holder to the gasket, and
then continue with the gas connection. The
flexible pipe is correct when:
– It cannot become hotter than room tempera-
ture or higher than 30 °C.
– It is no longer than 1500 mm.
– It does not compress.
– It is not subject to traction or torsion.
Ø By-pass in 1/100
mm.
35
39
Injector diam-
Usage
eter
mm
g/h
0,70
0,43
72,71
0,43
60,70
0,96
0,60
145,43
0,60
121,40
1,19
0,77
218,14
0,77
185,68
1,20
0,63
181,78
0,63
156,33
-
-
-
-
15

Advertisement