SmartBase MPC600F/MPC400 Chapter 4: Maintenance & Service

5.2.5 New SSSWs/parameters added to this model

#1 SSSW (service soft switch setting)
SW01 (service soft switch 01: error management)
Bit
0
1
2
3
4 (New) ##300 series service error code
5
6
7
[Bit 4]
Even when Bit0 is set to "Not output", you can select whether or not to output ##300 series Service
Error Codes, caused by hardware malfunction.
When "Output" is selected, ##300 series Service Error Codes are displayed and in reports.
When "Not Output" is selected, no Service Error Codes are displayed.
#1 SSSW (service soft switch setting)
SW15 (service soft switch 15: Dial-in FAX/TEL switching function setting)
Bit
0
1
2
3
4
5
6 (New) Detect continuous signal at
7
[Bit 6]
You may enable or disable detection of ROT continuous signal for FAX/TEL switching.
Normally, only ROT intermittent signals are detected for FAX/TEL switching. If you need to
detect both in view of exchange specifications, select
Function
Service error code
Error dump list
Not used
Copy function
Not used
Not used
User setting restriction
Function
Not used
Not used
Not used
Not used
Not used
Not used
FAX/TEL switching
Not used
1
Output
Output
No
Output
Setting possible
1
Yes
to enable detection.
4-42
0
Not output
Not output
Yes
Not output
Setting restricted
0
No

Hide quick links: