14. Operation under GSIF (Gigasampler Interface)
Windows 2000/XP
The GSIF interface of the Hammerfall DSP allows direct operation with Gigastudio, with up to
18 channels, 96 kHz and 24 bit. The new GSIF 2.0 is also supported with both audio and MIDI.
Gigastudio requires a lot of the computer's calculation power. An optimum performance is
achieved with a stand-alone GSIF PC. However, when using the Hammerfall DSP, the latency
is always the same as the one selected for ASIO operation. This can cause performance prob-
lems on slower machines when using GSIF and ASIO at the same time.
Please note that the W2k/XP driver fully supports multi-client operation, including the combina-
tion MME/ASIO. So for example Cubase, Gigastudio and Sonar can be used simultaneously,
provided each of these programs uses its own audio channels exclusively. For example ASIO
could use channels 1/2 and Gigastudio (with GSIF) channels 3/4 simultaneously, and so on.
Simultaneous operation of GSIF and ASIO requires to use different channels. For example,
if Cubase uses tracks 1/2 these tracks can not be used by Gigastudio.
Common Problems
Please note that Gigastudio is running unexpectedly in the background (thus blocking its as-
signed audio channels), as soon as the Gigastudio MIDI ports are used – even when Gigastudio
itself hasn't been started. This causes a lot of confusion, as the driver seems to behave com-
pletely buggy, and the user does not recognize the simple reason for it – for example simulta-
neous operation of ASIO and GSIF on the same channels.
In case Gigastudio loads well, loads gig files too, but won't play at all even when using the vir-
tual keyboard: Go to Hardware/Routing and select a valid MIDI input port. Note that blank is not
valid, but <none> is.

15. Using more than one Hammerfall DSP

The current drivers support operation of up to three Hammerfall DSP systems. Different I/O-
boxes may be used, in any combination. Multiface, Multiface II, Digiface, HDSP 9632 and
HDSP 9652 use the same driver, therefore can be used at the same time. Please note that only
one ADAT Sync In can be used (of course). All units have to be in sync, i.e. have to receive
valid sync information either via word clock or by using AutoSync and feeding synchronized
signals.
If one of the HDSP systems is set to clock mode Master, all others have to be set to clock
mode AutoSync, and have to be synced from the master, for example by feeding word
clock. The clock modes of all units have to be set up correctly in their Settings dialog.
If all units are fed with a synchronous clock, i.e. all units show Sync in their Settings dialog,
all channels can be used at once. This is especially easy to handle under ASIO, as the ASIO
driver presents all units as one.
Note: TotalMix is part of the hardware of each HDSP system. Up to three mixers are available,
but these are separated and can't interchange data. Therefore a global mixer for all units is not
possible.