Bryant 310AAV Installation, Start-Up, Operating And Service And Maintenance Instructions page 3

Single-stage deluxe, induced-combustion 4-way multipoise gas furnace
Hide thumbs Also See for 310AAV:
Table of Contents

Advertisement

5 15/16
5 15/16
[150.7]
[150.7]
AIR FLOW
AIR FLOW
5 1/2
5 1/2
[140.3]
[140.3]
Ø7/8
Ø7/8
8 7/16
8 7/16
[22.2]
[22.2]
[213.5]
[213.5]
ACCESSORY
ACCESSORY
9 7/8
9 7/8
[250.7]
[250.7]
Ø1/2
Ø1/2
[12.7]
[12.7]
27 3/4
27 3/4
THERMOSTAT WIRE ENTRY
THERMOSTAT WIRE ENTRY
[704.7]
[704.7]
33 1/4
33 1/4
[843.9]
[843.9]
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
21.6
21.6
[549.5]
[549.5]
BOTTOM INLET
BOTTOM INLET
28.39
28.39
[721.2]
[721.2]
29 29
[736.9]
[736.9]
NOTES:
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return ---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters.
(a.) For 800 CFM ---16 ---in. (406 mm) round or 14 1/2 x 12 ---in. (368 x 305 mm) rectangle.
(b.) For 1200 CFM ---20 ---in. (508 mm) round or 14 1/2 x 19 1/2 ---in. (368 x 495 mm) rectangle.
(c.) For 1600 CFM ---22 ---in. (559 mm) round or 14 1/2 x 22 1/16 ---in. (368 x 560mm) rectangle.
(d.) For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side
inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
A
CABINET
FURNACE SIZE
WIDTH
045---08/024045
14--- 3/16 (360)
045---12/036045
14--- 3/16 (360)
070---08/024070
14--- 3/16 (360)
070---12/036070
14--- 3/16 (360)
070---16/048070
17--- 1/2 (445)
090---14/042090
17--- 1/2 (445)
090---16/048090
21 (533)
090---20/060090
21 (533)
110---12/036110
17--- 1/2 (445)
110---16/048110
21 (533)
110---22/066110
21 (533)
135---16/048135
21 (533)
135---22/066135
24--- 1/2 (622)
155---20/060155
24--- 1/2 (622)
*135 and 155 size furnaces require a 5 or 6 ---in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for
complete installation requirements.
5.1
5.1
[130.5]
[130.5]
2 1/16
2 1/16
[51.6]
[51.6]
1.7
1.7
[43.5]
[43.5]
C
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY (2)
ACCESSORY (2)
1 15/16
1 15/16
[49.2]
[49.2]
AIR FLOW
AIR FLOW
2 5/16
2 5/16
3 7/16
3 7/16
[59]
[59]
A A
[86.8]
[86.8]
B
5 7/8
5 7/8
[148.5]
[148.5]
TOP OF CASING
TOP OF CASING
Ø7/8
Ø7/8
[22.2]
[22.2]
JUNCTION BOX
JUNCTION BOX
LOCATION
LOCATION
Ø1 3/4
Ø1 3/4
[44.5]
[44.5]
GAS ENTRY
GAS ENTRY
6.1
6.1
D
[155.7]
[155.7]
BOTTOM RETURN
BOTTOM RETURN
WIDTH
WIDTH
Fig. 1 --- Dimensional Drawing
Table 1—Dimensions - - In. (mm)
B
OUTLET
TOP & BOTTOM
WIDTH
FLUE COLLAR
LOCATION
12--- 9/16 (319)
9--- 5/16 (237)
12--- 9/16 (319)
9--- 5/16 (237)
12--- 9/16 (319)
9--- 5/16 (237)
12--- 9/16 (319)
9--- 5/16 (237)
15--- 7/8 (403)
11--- 9/16 (294)
15--- 7/8 (403)
11--- 9/16 (294)
19--- 3/8 (492)
13--- 5/16 (338)
19--- 3/8 (492)
13--- 5/16 (338)
15--- 7/8 (403)
11--- 9/16 (294)
19--- 3/8 (492)
13--- 5/16 (338)
19--- 3/8 (492)
13--- 5/16 (338)
19--- 3/8 (492)
13--- 5/16 (338)
22--- 7/8 (581)
15--- 1/16 (383)
22--- 7/8 (581)
15--- 1/16 (383)
6 13/16
6 13/16
[172.3]
[172.3]
5 7/8
5 7/8
[148.5]
[148.5]
5 5/8
5 5/8
[143.3]
[143.3]
5 7/16
5 7/16
[138.5]
[138.5]
1 15/16
1 15/16
[49.2]
[49.2]
TOP OF CASING
TOP OF CASING
4 13/16
4 13/16
[122.2]
[122.2]
9 9/16
9 9/16
[243.3]
[243.3]
Ø7/8
Ø7/8
27 3/4
27 3/4
[22.2]
[22.2]
[704.7]
[704.7]
J.BOX PROVISION
J.BOX PROVISION
29 9/16
29 9/16
Ø7/8
Ø7/8
[22.2]
[22.2]
[750.7]
[750.7]
ACCESSORY
ACCESSORY
KNOCK OUTS FOR
KNOCK OUTS FOR
3/4
3/4
VENTING(5
VENTING(5
[19.1]
[19.1]
PLACES)
PLACES)
D
C
BOTTOM
INLET WIDTH
12--- 11/16 (322)
12--- 11/16 (322)
12--- 11/16 (322)
12--- 11/16 (322)
16 (406)
16 (406)
19--- 1/2 (495)
19--- 1/2 (495)
16 (406)
19--- 1/2 (495)
19--- 1/2 (495)
19--- 1/2 (495)
23 (584)
23 (584)
3
8 5/8
8 5/8
[219]
[219]
AIR FLOW
AIR FLOW
19 19
[481.7]
[481.7]
OUTLET
OUTLET
Ø1/2
Ø1/2
[12.7]
[12.7]
7 13/16
7 13/16
9 11/16
9 11/16
THERMOSTAT WIRE ENTRY
THERMOSTAT WIRE ENTRY
[197.8]
[197.8]
[245.4]
[245.4]
Ø1 3/4
Ø1 3/4
[44.5]
[44.5]
GAS ENTRY
GAS ENTRY
14 7/8
14 7/8
Ø7/8
Ø7/8
[337.3]
[337.3]
[22.2]
[22.2]
(BOTH SIDES)
(BOTH SIDES)
ACCESSORY
ACCESSORY
1 1/4
1 1/4
[31.8]
[31.8]
22 1/16
22 1/16
1
[560]
[560]
[25.4]
[25.4]
SIDE INLET
SIDE INLET
(BOTH SIDES)
(BOTH SIDES)
VENT
SHIP WT
CONNECTION
LB (KG)
SIZE
4 (102)
104 (47)
4 (102)
107 (49)
4 (102)
111 (50)
4 (102)
115 (52)
4 (102)
126 (57)
4 (102)
127 (58)
4 (102)
140 (64)
4 (102)
146 (66)
4 (102)
135 (61)
4 (102)
146 (66)
4 (102)
152 (69)
4 (102)*
149 (68)
4 (102)*
163 (74)
4 (102)*
170 (77)
11 7/16
11 7/16
[290.7]
[290.7]
A10290

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

310javStart-up and

Table of Contents