When this Message Appears

Message
[Registration Error]
Registration error. Out of
free memory space.
[Copy file error]
Copy file error.
No available memory.
[Moving file error]
Moving file error.
No available memory.
[Corrupted file Recovery]
Detected corrupted file.
*Some data may not be
recovered.
Select Yes to continue.
[Corrupted file Recovery
Error]
Corrupted file recovery
error.
Backup file may also be
damaged.
Select Yes to delete this
file.
[Initializing error]
Initializing error.
5
70
Problems and Solutions
Problem:
• There is not enough free space in the registering memory
card.
Solution:
• The maximum memory card capacity for this unit is 2GB.
• If a unit-specific file is being created from contents with a large
file size, divide the content source file and convert the file into
smaller size contents.
• Divide the unit-specific file to copy/move large unit-specific
files. Copy the unit-specific file and create two files in the
library. Divide the unit-specific files into (first and second)
halves by deleting pages and convert the original file into two
smaller files.
• Create/copy/move fewer files when creating multiple content
source files at one time or copying/moving multiple unit-
specific files.
• Increase the amount of free space by backing up or deleting
unit-specific files that are not required by the memory card or
non unit-specific files.
Problem:
• A folder or unit-specific file is damaged.
Solution:
• Refer to "Recovering Damaged Files" on page 66.
Problem:
• A folder or the backup of the unit-specific file is damaged.
Solution:
• Refer to "Recovering Damaged Files" on page 66.
Problem:
• A non unit-specific BRVDOC folder exists in the memory card.
Solution:
• Delete the non unit-specific BRVDOC folder.