Canon RE-350 Control Interface Commands Manual page 39

Video visualizer
Hide thumbs Also See for RE-350:
Table of Contents

Advertisement

Document Lights: On
• Function:
Turns on the document lights above the document table. (Also, the Auto-White Balance will be adjusted once.)
Note: If the Backlight is already on, and the Document Lights are turned on, then the Backlight will be turned off
automatically and only the Document Lights will remain on.
• Timing of the "C-response Packet" sent to the PC:
Right after turning on the lights.
• The parameter of the "C-response Packet":
$0000 fixed
• The maximum operation time (msec):
500 millisecond
• Command format:
Header
ID number
$10
Document Lights: Off
• Function:
Turns off the Document Lights above the document table. (Also, the Auto-White Balance will be adjusted once.)
• Timing of the "C-response Packet" sent to the PC:
Right after turning off the lights.
• The parameter of the "C-response Packet":
$0000 fixed
• The maximum operation time (msec):
500 millisecond
• Command format:
Header
ID number
$10
The
responds in
RE-350
be still working on the
AWB
Command
$ 8 *
$ 5 8
Command
$ 8 *
$5 8
msec with a C-response data packet after the reception of this command, but it will
500
adjustment. (The real
Parameter MSH
$ 0 0
Parameter MSH
$ 0 1
operation time will be longer than
AWB
Parameter LSH
$ 0 0
Parameter LSH
$ 0 0
msec.)
500
39

Advertisement

Table of Contents
loading

Table of Contents