Installing Dimms; Mezzanine Card Option - HP BL2x220c - ProLiant - G5 Server A User Manual

Hp proliant bl2x220c generation 5 server blade user guide
Hide thumbs Also See for BL2x220c - ProLiant - G5 Server A:
Table of Contents

Advertisement

Install only ECC PC2-5300 Registered DDR2 SDRAM DIMMs that meet the following specifications:
Supply voltage: 1.8 V
o
Bus width: 72 bits
o
Always install DIMMs in sequence (1A, 2B, 3C, 4D).
Each server supports up to 16 GB of memory when 4-GB memory modules are installed. The amount of
memory supported is independent of the processor configuration.
Each server supports multiple memory modes, based on DIMM population. The system will default to
Advanced ECC. To select a mode, use RBSU

Installing DIMMs

To install the component:
Power down the server blade (on page 13).
1.
Remove the server blade (on page 14).
2.
Access the internal server components (on page 14).
3.
Open the DIMM slot latches.
4.
IMPORTANT:
Install the DIMM.
5.
Install the server B assembly
6.
Install the server blade
7.

Mezzanine card option

Optional mezzanine cards are classified as Type I mezzanine cards and Type II mezzanine cards. The
server blade supports only Type I mezzanine cards.
("HP ROM-Based Setup
Always install memory in pairs of two identical DIMMs.
("Install server B
("Installing a server
blade" on page 19).
Utility" on page 45).
assembly" on page 15).
Hardware options installation 24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant bl2x220c g5

Table of Contents