Ndis 4.0 (Windows Nt) Driver Messages - IBM 866631Y - Netfinity 7100 - 8666 Hardware Maintenance Manual

Hardware maintenance manual
Table of Contents

Advertisement

Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet
controller (continued)
PCNTNW-NW-126 The group bit in the node address override was cleared.
Explanation: The IEEE address has a group bit that indicates that
an address belongs to a group of stations. This bit is used only as a
destination address; it cannot be used as a source address. You
tried to enter a source address with this bit set. The driver cleared
the group bit of the source address. Action: None necessary,
message is for information only.
PCNTNW-NW-127 The local bit in the node address override was set.
Explanation: The local bit in the IEEE address format indicates that
the addresses are being managed locally. If you use the node
address override capabilities of this driver to enter a new address,
the local bit must be set. You entered an address without the local
bit set. The driver has set the local bit. Action: None necessary,
message is for information only.
PCNTNW-NW-164 The device was not found.
Explanation: The driver cannot find an Ethernet controller in the
server. Action:Verify that the Ethernet controller is enabled. If the
Ethernet controller is enabled, go to "Starting the diagnostic
programs" on page 14 to run the diagnostic programs.
PCNTNW-NW-165 The device was not found at IOADDRESS.
Explanation: The Ethernet controller cannot be found at the I/O
address specified. Action:The Ethernet controller does not require a
parameter for the I/O address. Remove the I/O address parameter.
PCNTNW-NW-167 PCI scan specified, device not found.
Explanation: The driver cannot locate the Ethernet controller on
the PCI bus. Action:Verify that the Ethernet controller is enabled. If
the problem persists, go to "Starting the diagnostic programs" on
page 14 to run the diagnostic programs.
PCNTNW-NW-180 The DMA parameter is not necessary for PCI device.
Explanation: The Ethernet controller does not require a DMA
setting. Action:None necessary, message is for information only.

NDIS 4.0 (Windows NT) driver messages

This section contains the error messages for the NDIS 4.0 drivers. The explanation
and recommended action are included with each message.
Table 4. NDIS (Windows NT) driver messages for the Ethernet controller
PermaNet
No Secondary Adapter Found. Grouping Mode is disabled.
Server:
Explanation:The failover option requires an adapter that is compatible
with the device driver of the Ethernet controller on the system board.
No such adapter was found. Action:Make sure the correct adapter is
installed.
27
Diagnostics