(2) Hold sections "X" of the front cover and pull out the front cover.
NOTE: Do not pull the front cover away from the machine. The sub PCB flat cable
fixed to the front cover is connected to the main PCB mounted in the bottom cover.
(3) Unhook the sub PCB flat cable from the cable guide on the cover lock lever mounted
on the inside the body cover.
(4) Disengage the body cover from the bottom cover.
NOTE: Do not pull the body cover away from the bottom cover. The sensor PCB
flat cable and tape end sensor harness fixed to the body cover are connected to the
main PCB mounted in the bottom cover.
Fig. 2.2-4 Disengaging the Body Cover from the Bottom Cover
Fig. 2.2-3 Disconnecting the Front Cover
II - 11