INSPECTION
Perform
the tests below
to ensure
proper
operation
of the GFCI.
Record your test on the GFCI test card provided
on the generator.
Before each use:
If the generator
is stored outdoors,
unprotected
from the weather, test
the GFCI receptacle
before
each use as described
in the monthly
inspection.
Mdnthly:
Under normal operating
conditions,
perform the GFCI test monthly.
1. Unplug all appliances
from the
generator.
2. Start the engine.
3. Turn the circuit breaker ON.
4. Make sure the auto-throttle
switch
is OFF.
5. Press the TEST BUTTON
-The
RESET
BUTTON
should
extend with a click.
-If the RESET BUTTON does not
extend,
contact
an authorized
Honda generator
dealer.