Electrical Connections - Berkel FMS60 Owner's/Operator's Manual

60 quart mixer
Table of Contents

Advertisement

Electrical and grounding connections must comply with the applicable portion
of the National Electrical Code and/or other Local Electrical Codes.
disconnect the electrical power to the machine and follow lockout/tagout
procedures. do not remove side cover.
A hole for the 3/4" trade-size conduit is located in the top left side of the pedestal. Remove top cover. Make
electrical connections to supply harness wires in wiring area as follows:
Single-Phase Mixer:
Connect field supply lead L1 to supply harness wire "SERVL1".
Connect field supply lead L2 to supply harness wire "SERVL2".
Cut off stripped portion of "SERVL3" harness wire and wrap securely with electrical tape to insu-
late the exposed conductor.
Connect ground wire to ground lug on the mixer.
Three-Phase Mixer:
Connect field supply lead L1 to supply harness wire "SERVL1".
Connect field supply lead L2 to supply harness wire "SERVL2".
Connect field supply lead L3 to supply harness wire "SERVL3".
Connect ground wire to ground lug on the mixer.
Assure all wires and wire connections are inside wiring area and away from belt.
For wiring details, reference wiring diagram located on the inside of the TOP COVER.
Reinstall TOP COVER.
FMS60 Owner/Operator Manual

ELECTrICAL CONNECTIONS

– 4 –

Advertisement

Table of Contents
loading

Table of Contents