OPERATION
AC Receptacle Selection
The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle 4, the 240-volt receptacle, has two
powered terminals, 4A and 4B.
: Except EG4000CL
Power Producing Circuits
This generator is equipped with two power generating circuits.
When the voltage selector switch is in the 120V/240V position, each
of the two power producing circuits supplies power to specific
receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles 1, 2, and 3.
120V/240V
POWER
CIRCUIT 1
POWER
CIRCUIT 2
28
120V 30A
120V 20A (in total)
120V 20A (in total)
&
120V/240V 20A (EG4000CL)
4A
4B
120V/240V 30A (EG5000CL, EG6500CL)
4A
4B
POWER CIRCUIT 1
120V ONLY
POWER CIRCUIT 2