Ac Receptacle Selection; Power Producing Circuits - Honda EM6500SX Owner's Manual

Hide thumbs Also See for EM6500SX:
Table of Contents

Advertisement

OPERATION

AC Receptacle Selection

The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle 4, the 240-volt receptacle, has two
powered terminals, 4A and 4B.
VOLTAGE SELECTOR
SWITCH
RECEPTACLE ①
*: Except EM4000SX

Power Producing Circuits

This generator is equipped with two power generating circuits.
When the voltage selector switch is in the 120V/240V position, each of
the two power producing circuits supplies power to specific
receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles 1, 2, and 3.
POWER
CIRCUIT B
POWER
CIRCUIT A
34
TERMINAL
TERMINAL
*
RECEPTACLE ②
GFCI RECEPTACLE
(120 V 20 A DUPLEX RECEPTACLE)
120 V/240 V
TERMINAL
TERMINAL
RECEPTACLE ④
<EM4000SX>
RECEPTACLE ④
RECEPTACLE ③
GFCI RECEPTACLE
(120 V 20 A DUPLEX RECEPTACLE)
120 V ONLY
POWER CIRCUIT A
POWER CIRCUIT B