Multimeter disturbance:
•
VDC, VAC, and VAC+DC with STL120 and short ground lead.
•
OHM, CONT, DIODE, and CAP with STL120, and black test lead to COM.
Disturbance less than 1% of full scale
Frequency range 10 kHz to 27 MHz
VDC, VAC, VAC+DC
OHM, CONT, DIODE
CAP
Frequency range 27 MHz to 1 GHz
VDC, VAC, VAC+DC
OHM, CONT, DIODE
CAP
Disturbance less than 1% of full scale
Frequency range 1.4 GHz to 2 GHz
VDC, VAC, VAC+DC
OHM, CONT, DIODE
CAP
Frequency range 2 GHz to 2.7 GHz
VDC, VAC, VAC+DC
OHM, CONT, DIODE
CAP
Test tool ranges not specified in table 3 may have a disturbance of more than 10% of full scale
Table 3
E= 3 V/m
500 mV to 1250V
50 Ω to 30 MΩ
50 nF to 500 μF
500 mV to 1250V
50 Ω to 30 MΩ
50 nF to 500 μF
E= 3 V/m
500 mV to 1250V
50 Ω to 30 MΩ
50 nF to 500 μF
4
Specifications
Safety
E= 10 V/m
500 mV to 1250V
50 Ω to 30 MΩ
50 nF to 500 μF
500 mV to 1250V
50 Ω to 30 MΩ
50 nF to 500 μF
E= 1 V/m
500 mV to 1250V
50 Ω to 30 MΩ
50 nF to 500 μF
73