Code 128 Subset A - Kyocera ECOSYS FS-1320D User Manual

Pcl barcode flash 3.0 user's manual
Hide thumbs Also See for ECOSYS FS-1320D:
Table of Contents

Advertisement

3.6.26 Code 128 Subset A

Type / properties:
Linear code
Activation sequence:
<Esc>(s24701T<Base Data><Stop Character>
For an explanation on selecting the stop character and the optional parameters, see
chapters 3.2.1. and 3.2.6.
Default - parameters:
v parameter
p parameter
b parameter
Additional properties:
Size of base data:
Character set:
Example:
<Esc>(s24701T1234567890ABC<CR>
1 to 100
All printable characters from ASCII 00 to 95
90

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents