Table 4. POST error messages (continued)
POST message
Description
602
Invalid diskette boot record
Action: Take the following steps to correct the problem:
1. Replace the diskette.
2. If the problem remains, make sure that the diskette drive cables are correctly and securely
3. If the problem remains, replace the diskette drive.
If the problem remains, call for service.
604
An error occurred during a diskette drive test.
Action: Take the following steps to correct the problem:
1. Verify that the Configuration/Setup Utility program correctly reflects the type of diskette
2. Run the diagnostic tests. If the diagnostic tests fail, call for service.
662
A diskette drive configuration error occurred.
Action: If you removed a diskette drive, make sure that the diskette drive setting is correct in
the Configuration/Setup Utility program. If the setting is not correct, change it.
If the problem remains, call for service.
962
A parallel port configuration error occurred.
Action: If you changed a hardware option, make sure that the parallel port setting is correct in
the Configuration/Setup Utility program. If the setting is not correct, change it.
If the problem remains, call for service.
11xx
An error occurred during the system-board serial port test.
Action: If you have a serial device attached to your computer, verify that the serial cable is
connected correctly. If it is, use the following procedure:
1. Turn off the computer.
2. Disconnect the serial cable from the serial port.
3. Wait five seconds; then, turn on the computer.
If the POST error message does not reappear, either the serial cable or the device is probably
failing. See the documentation that comes with the serial device for additional testing
information.
If the POST error message reappears, call for service.
1162
The serial port configuration conflicts with another device in the system.
Action: Take the following steps to correct the problem:
1. Make sure the IRQ and I/O port assignments needed by the serial port are available.
2. If all interrupts are being used by adapters, you might need to remove an adapter to make
1600
The Advanced System Management processor is not functioning.
Action: Take the following steps to correct the problem:
1. Verify that the jumpers for the system-management processor are set correctly.
2. Disconnect the computer from all electrical sources, wait for 30 seconds, reconnect the
If the problem remains, call for service.
1601
An Advanced System Management Flash update is needed.
Action: Download and install the latest Advanced System Management flash update.
68
IBM IntelliStation Z Pro Type 6221: User's Guide
connected.
drive that you have installed.
an interrupt available to the serial port, or force other adapters to share an interrupt.
computer to the electrical sources, and restart the computer.