EMC CLARiiON CX300, CX500, CX500i, and CX700 Storage Systems Configuration Planning Guide
device stops participating. A switch also provides
server-to-storage-system access control and point-to-point
connections.
Server
Server
SP
SP
Storage System

Switch and Point-to-Point Connections

You can cascade switches (connect one switch port to another switch)
for additional port connections.
Switch Zoning
Switch zoning lets an administrator define paths between connected
nodes based on the node's unique World Wide Name. Each zone
includes a server adapter and/or one or more SPs. EMC recommends
single-initiator zoning, which limits each zone to a single HBA port
(initiator). The current connection limits are outlined in Table 1-2.
Connection Limits
Maximum HBA Ports
Storage System
CX300
CX500
CX700
Server
SP
SP
Storage System
Maximum HBA Ports
per SP
per Storage System
32
128
64
256
64
512
EMC1805