Built-in single-zone expander keypad

Advertisement

(between the front and back case) and gently
twist to release the side locking tab.
other side. Refer to Figure 1 for location of the case
back release snaps and locking tabs.
ARMED
READY
NOTE:
TO REMOVE CASE BACK
PUSH IN THE TWO MOUNTING
SNAPS LOCATED ALONG THE
BOTTOM OF THE KEYPAD
AND LIFT UP.
RETAINING
SNAPS
Figure 1. Removing the Case Back
2.
Mount the case back to a wall or to an electrical
box using the 25mm-long self-tapping screws
supplied (anchors for drywall are not supplied).
If you wish to tamper-protect the keypad for removal
from the wall, use an additional mounting screw in the
tamper hole in the case back (see Figure 2 for location).
3.
Pass the four power/data wires and zone wires
through the opening in the case back. If surface
wiring is being used, wiring may be routed through
the top or the bottom left-side breakout in the case
back. See Figure 2. The breakouts must be
punched out using a screwdriver before mounting
the case back. If desired, wires may be strain-
relieved to the wire tie point on the inside of the
case back with a tie wrap (not supplied).
BREAKOUT
FOR SURFACE
WIRING
BREAKOUT
WIRE
FOR SURFACE
WIRING
POINT
Figure 2. Wiring Entry (Case Back)
4. Connect the power/data wires to the four screw
terminals on the keypad's PC board marked as
shown in Figure 3 and as follows:
WWW.DIYALARMFORUM.COM
Repeat for the
LOCKING
TAB
USE AN ADDITIONAL
MOUNTING SCREW
HERE IF BACK CASE
TAMPER WILL BE USED
MOUNTING
TIE
HOLES
6151-001-V0
WWW.DIYALARMFORUM.COM
Keypad
GM
Data Out
GND
+
+12VDC
LY
Data In
5. Connect the wires for the 2K EOLR zone to the
screw terminals on keypad PC board as shown in
Figure 3 and as follows:
Keypad
ZN1
LEGEND
= -
NOTE
THE CONTROL PANEL
MUST SUPPORT
DOUBLE BALANCED
RESISTORS
[Y] DATA IN
[+] +12VDC IN
[-] GROUND (-12V)
[G] DATA OUT
G
Figure 3. Wiring Details
6. Reattach the keypad to the mounted case back.
Attach the top of the keypad first, and then press
the bottom section down until it snaps into place
securely.
SETTING THE KEYPAD OPTIONS
For UL (and ETL) commercial burglary installations,
U U U U L L L L
the zone must be programmed as a 24-hour audible
zone type.
The 6151 allows seven items to be programmed via
local keypad programming mode:
• Keypad address
• Zone expander enable
• Zone expander address
• Zone type
These settings are maintained even when keypad
power is removed.
- 2 -
Wiring Table
Control Panel
Color
Data In
Green
− Aux Pwr
Black
+ Aux Pwr
Red
Data Out
Yellow
Wired Zone
+ Zone 1
- Zone 1 return
DOUBLE
CONVENTIONAL
BALANCED
EOLR
2K
2K
TAMPER
2K
CONTACTS
N.O.
TAMPER
2K
N.C.
CONTACTS
OR
Y
ZN
• Tamper enable
• Display option
• Sound option