This dryer can be converted
to exhaust
out the right side, left side, or through
the bottom.
Contact
your local dealer to have the dryer converted.
Special
provisions
for
mobile
home
installations
The exhaust
vent must be securely
fastened to a noncombustible
portion
of the mobile
home
structure
and must not terminate
beneath
the mobile
home. Terminate
the exhaust
vent
outside.
B
A. Standard rear offset exhaust installation
B. Zeft or right side' exhaust installation
C. Bottom exhaust installation (not an option with
ped_'stal installations)
Alternate
installations
for
close clearances
Venting
systems come
ill many varieties•
Select the type best for your installation.
Two close-
clearance
installations
are shown.
Refer to the manufacturer's
instructions.
i
_==_-
\d
aL_[. =---_
V,';'"
ill;
\\
I
A
B
A. Over-the-top
installation (also available" with one
offset elbow)
B. P_'ri_cope installadon
NOTE: The following
kits for close clearance
alternate
installations
are available
for purchase.
Please see the "Assistance
or Service"
section
to order.
Over-the-Top
Installation:
Part Number
4"¢96028
Periscope
Installation
(For use with
dryer vent to wall vent mismatch):
Part Number
4";960"¢7 - 0" (0 cm) to 18" (45.72 cm) mismatch
Part Number
4";9601 I - 18" (45•72
cm) to 29" (7"L66
cm) mismatch
Part Number
4";96014
- 29" (73•66
cm) to 50" (127 cm) mismatch
Determine
vent path
Select the route that will provide
the straightest
and most direct
path outdoors.
Plan the installation
to use the fewest
number
of elbows
and turns•
When
using elbows
or making
turns,
allow as much
room as possible.
Bend vent gradually
to avoid kinking.
Use the fewest 90 ° turns possible.
Determine
vent length
and elbows
needed
for best drying
performance
Use the following
Vent system chart to determine
type of vent material
and hood
combinations
acceptable
to use.
NOTE:
Do not use vent runs longer than those specified
in the Vent system chart.
Exhaust
systems longer than those specified
will:
Shorten
the life of the dryer.
Reduce performance,
resulting
in longer drying
times and increased
energy
usage.
The Vent system chart provides
venting
requirements
that will
help to achieve
the best drying
performance.