Replacement
4 )
Use a Phillips screwdriver to loosen
the "Lamp unit cover fixing screw"
(3 screws) for the lamp unit to be
replaced until the screws turn freely.
Hold the "Handle" of the "Lamp unit"
and gently pull the lamp unit out from
the projector.
Lamp unit fixing screws
Handle
5 )
Replace the new LAMP unit in correct
direction.
Lamp unit installation
guide
6 )
Use a Phillips screwdriver to securely
tighten the 2 "Lamp Unit cover fixing
screw" for lamp unit.
Note
When the lamp unit is replaced, the duration of usage
z
time will be reset to "0".
80
- ENGLISH
Groove for lamp unit
installation guide
7 )
Open the "Exhaust Fan" as illustrated,
and remove the "Air Filter" from "Air
filter housing".
Air filter housing
Air filter
8 )
Mount a new "Air Filter" in the
"Air Filter housing", and close the
"Exhaust Fan".
9 )
Close the "Exhaust Fan" cover in the
reverse procedure of Step (3). Then,
tighten and secure the "Exhaust
fan fixing screw" (1 piece) using a
Phillips-head screwdriver.
10 )
Mount the "Air Filter/Lamp Unit
cover", and retighten "Air Filter/Lamp
Unit cover fixing screw" (1 piece) of
this cover securely.
Handle