Konica Minolta bizhub C364/C284/C224
Specification & Installation Guide
bizhub C364/C284/C224 Specifications
Print speed (ppm)*:
Color/B&W (double sided/plain paper):
continued
Size
11" x 17"
8.5" x 14"
8.5" x 11"P
8.5" x 11"L
5.5" x 8.5"L
8" x 13"L
*Using 1st Tray
Magnification
1.0 (full size: 1.00+_0.5% or less)
ratios
Enlarge: 121.4%, 129.4%, 154.5%, 200%
Reduce: 78.5%, 73.3%, 64.7%, 50.0%
Minimal: 93%
Stored Zoom Ratios: 3
"Minimal" zoom ratio (90% to 99.9%)
Multiple copies
1 to 9,999 sheets
Density control
Copy Density: Manual Density Adjustment
(9 Levels); Background Density: Automatic
and Manual Density Adjustments (9 levels)
Power
120V, 12 A, 60 Hz
requirements
Power
1.5 kW or less
consumption
TEC Value
C364: 2.43 kWh
C284: 1.83 kWh
C224: 1.63 kWh
Dimensions
24.2" (W) x 27" (D) x 31" (H)
(with control panel)
Space requirements* 36.9" (W) x 47.8" (D) x 30.7" (H)
Memory (available
2 GB, (250 GB HDD) (std); 2 GB (opt).
hard disk space)
Weight
Approx. 185.18 lb.
* The indicated space requirements represent the space required to pull out
the paper tray and the tray extension of the bypass tray and with the ADF open.
2
continued
C364 C284 C224
18
14
14
20
16
16
36
28
22
25
20
20
36
28
22
20
16
16

Duty Cycle

Up to C364: 125,000, C284: 100,000, C224: 80,000.
Maximum monthly copy/print volume supported under
standard vendor supplied service. Defines the upper
end of the expected customer volume for the device.
Customers should consider multiple machines if average
monthly volume approaches duty cycle on continual basis.

Environmental Requirements

Temperature
Humidity
Noise during operation (BW/Color)
Noise during feeder operation
(FS-534/FS-533)
Noise during standby
Ozone emission

Electrical Requirements

Line Options
Dedicated
Voltage:
110 V/120
to 127 V/220
to 240 V AC
Amperage
12 A
Cycles
60 Hz
NEMA Part No:
5-15R
Cord Length
6.6 ft.
Note: The main electrical outlet must be located within 6.6 feet from the right rear
corner of the bizhub C364/C284/C224 main unit.
50° F to 86° F
15% to 85%
C364: 71.6 dB/71.8 dB
C284: 68.8 dB/69.4 dB
C224: 66.7 dB/67.6 dB
C364: 69.2 dB or less
C284: 68.0 dB or less
C224: 67.6 dB or less
40.5 dB or less
Color: 3.0 mg/h
Color: 1.5 mg/h
NEMA Diagram for 5-15R