Disassembly Instructions - Bosch HMV9302 - 1.8 cu. Ft. Microwave Service Manual

Service manual
Hide thumbs Also See for HMV9302 - 1.8 cu. Ft. Microwave:
Table of Contents

Advertisement

DISASSEMBLY INSTRUCTIONS

IMPORTANT NOTES:
UNIT MUST BE DISCONNECTED FROM ELEC-
TRICAL OUTLET WHEN MAKING REPAIRS, RE-
PLACEMENTS, ADJUSTMENTS AND CONTIN-
UITY CHECKS. WAIT AT LEAST ONE MINUTE,
UNTIL THE HIGH VOLTAGE CAPACITOR IN THE
HIGH VOLTAGE POWER SUPPLY HAS FULLY
DISCHARGED.
THE CAPACITOR SHOULD BE DISCHARGED BY
USING INSULATED WIRE - I.E. TEST PROBE
CONNECTED TO 10K-OHM RESISTOR IN SERIES
TO GROUND.
WHEN RECONNECTING THE WIRE LEADS TO
ANY PART, MAKE SURE THE WIRING CONNE-
CTIONS AND LEAD COLORS ARE CORRECTLY
MATCHED ACCORDING TO THE OVERALL CIR-
CUIT DIAGRAM. (ESPECIALLY SWITCHES AND
HIGH VOLTAGE CIRCUIT.)
A. REMOVING POWER AND CONTROL
CIRCUIT BOARD (Figures 1, 2 and 3)
(1) Remove a screw securing the control panel
assembly to the oven cavity.
(2) Remove the control panel with pushing it upward.
(3) Remove the connector (CN1) and wire leads
(Relay6) from the circuit board.
Screw
Power
Transformer
Control Panel
(CN5)
(CN5)
-For the sensor
(CN2)
model only
(CN2)
Relay 2
(Relay 2)
(CN1)
Figure 1
(4) Remove 3 screws securing the circuit board.
(5) Remove the FPC connector from the terminal
socket following "HOW TO REMOVE THE FPC
CONNECTOR" on the next page.
(6) Remove the circuit board from the control bracket
carefully.
Control Bracket
FPC Connector(S1)
Circuit Board
7-4
Circuit Board
Figure 2
Figure 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hmv9305Hmv9302Hmv9306Hmv9307Hmv9303

Table of Contents