Bosch HMV9302 Installation Instructions Manual
Bosch HMV9302 Installation Instructions Manual

Bosch HMV9302 Installation Instructions Manual

Over-the-range microwave
Hide thumbs Also See for HMV9302:

Advertisement

Available languages

Available languages

Over-the-Ra nge Microwave
In stallation
Instructions
For Models: HMV9302.
HMV9303.
HMV9305,
HMV9306,
HMV9307
PLEASE READ ENTIRE INSTRUCTIONS
BEFORE PROCEEDING
MPORTANT: Save these instructions for the local electrical inspector's use.
INSTALLER: Please leave these Installation nstructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Printed in Korea
P/No.: 3828W5U0503

Advertisement

Table of Contents
loading

Summary of Contents for Bosch HMV9302

  • Page 1 Over-the-Ra nge Microwave In stallation Instructions For Models: HMV9302. HMV9303. HMV9305, HMV9306, HMV9307 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING MPORTANT: Save these instructions for the local electrical inspector's use. INSTALLER: Please leave these Installation nstructions with this unit for the owner.
  • Page 2: Your Safety First

    YOUR SAFETY FIRST BEFORE YOU START ° Proper installation is the installer's responsibility! - Read the entire manual before you begin. The Model number label is located on the oven front. See Figure 1. Mounting plate is located on back side of microwave oven. See Figure 2. BE SURE TO READ THE FOLLOWING SAFETY INSTRUCTIONS:...
  • Page 3 YOUR SAFETY FIRST • THIS APPLIANCE MUST BE GROUNDED! - If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. •...
  • Page 4 YOUR SAFETY FIRST = MAKE SURE HAVE ENOUGH SPACE SUPPORT. - Mount the oven against a flat, vertical wall, so it is supported by the wall. The wall should be constructed minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath. - ATTACH AT LEAST ONE of the two lag screws...
  • Page 5: Parts, Tools

    PARTS, TOOLS, MATERIALS THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN: NOTE: Depending on your ventilation requirements, you may not use all of these parts. Damper/duct connector One power cord clamp (for roof vented or wall vented installation) One dark-colored mounting screw Not Actual...
  • Page 6: Parts, Tools, Materials

    PARTS, TOOLS, MATERIALS YOU WILL NEED THE FOLLOWING TOOLS AND MATERIALS FOR THE INSTALLATION: heavy covering top. Carton other material for the counter Clear tape Stud finder or thin nail. (for taping the templates to the wall) Keyhole saw (for the power cord hole) Saber saw (for cutting vent holes for roof or wall venting)
  • Page 7: Electrical Connections

    STEP 1: PREPARE THE ELECTRICAL CONNECTIONS NI NG AVOID ELECTRICAL SHOCK! THIS APPLIANCE MUST BE GROUNDED! 1. Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 4 Detail. NOTE: The outlet should be on a circuit dedicated to the...
  • Page 8: Prepare The Venting System

    STEP 2: PREPARE THE VENTING SYSTEM NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length are shown in Figure 9, page 9. ,WARNING:FIRE HAZARD THIS OVEN MUST BE PROPERLY VENTED! You may vent your oven in one of three ways: Roof-venting If your oven is located on an outside wall near the roof, as in Figures 5 (3_/4'' x 10"...
  • Page 9: Standard Fittings

    STEP 2: PREPARE THE VENTING SYSYTEM STANDARD FITTINGS NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension duct installed between the damper assembly and the adapter to prevent the exhaust damper's sticking.
  • Page 10: Prepare The Venting Blower

    STEP 3: PREPARE THE VENTING BLOWER Your microwave oven is shipped with the blower assembled for roof venting. You need to adjust the blower you want wall-venting or room-vented (recirculating) installation. , WARNING ELECTRICAL SHOCK HAZARD! UNPLUG UNIT BEFORE WORKING ON IT, •...
  • Page 11: Wall-Vented Installation

    STEP 3: PREPARE THE VENTING BLOWER WALL-VENTED INSTALLATION: back plate blower unit 1. Remove one blower unit mounting screw and one blower plate screw. Remove the blower plate from cabinet. See Figure blower plate mounting screws 2. Carefully lift the blower unit out of the microwave oven.
  • Page 12 STEP 3: PREPARE THE VENTING BLOWER mounting screws laust blower unit ports exhaust ports Figure 17 <Option> blower unit mounting screws Figure 18 ROOM-VENTED (Recirculating) INSTALLATION: 1. Remove one blower unit mounting screw and one blower plate screw. Remove the blower plate from cabinet.
  • Page 13 STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION MEASURE AND TACK / TAPE UP THE TEMPLATES 1. Using a plumb line and (metal) measuring tape, find and © mark the vertical center line on the back wall, as in Figure 22.
  • Page 14 STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION DRILLING THE HOLES IN THE WALL AND UPPER CABINET: WARNING BE VERY CAREFUL WHEN DRILLING HOLES INTO THE WALL. Electrical wires could be concealed behind the wall covering and if the drill hits them you could get an electric shock. 1.
  • Page 15 STEP 5: INSTALL THE MOUNTING PLATE TO THE WALL CONNECTING THE OVEN TO A WALL STUD: 3/16" Hole on Studs 3/4" Hole on Drywall Only NOTE: The oven must be connected to at least one wall stud. Minimum 66" From the Floor 1.
  • Page 16 STEP 5: INSTALL THE MOUNTING PLATE TO THE WALL TO PREPARE THE REAR WALL CUTOUT OPENING AND EXHAUST ADAPTOR/MOUNTING PLATE FOR WALL-VENTED: 1. Place the mounting plate against the rear wall as described in step 5 item 1 (page 15). 2.
  • Page 17: Attach The Oven To The Wall

    STEP 6: ATTACH THE OVEN TO THE WALL WARNING You will need two people to lift this microwave. Failure to use more than one person could result in power cord personal injury. 1. Carefully lift microwave oven and hang it on support tabs (See Figure 26 on the page 15) at the bottom of the mounting...
  • Page 18 STEP 6: ATTACH THE OVEN TO THE WALL 5. Roof vented installation: See Figure 32 Install ductwork through the vent opening in the upper damper cabinet. Complete the venting system through the roof according to the method needed. See "PREPARE THE VENTING SYSTEM,"...
  • Page 19 I_lectromdnagers Four b micro-ondes avec hotte Instructions d'installation For Models: HMV9302, HMV9303, HMV9305. HMV9306 HMV9307 PRIEREDE LIRETOUTES LES INSTRUCTIONSAVANTDE PROCEDER,A, [ .'iNSTALLATION. IMPORTANT:Conserverces instructionspour que I'inspecteurlocalpuissev6rifierI'installation. INSTALLATEUR:Pri_rede remettreces instructions au propri6taire apr#s J'installation. PROPRIETAIRE : Conserverces instructionspour r6f_rencefuture. Imprim& en Cor&e...
  • Page 20 VOTRE sr:..CUR|TP:.. D 'ABORD AVANT DE COMMENCER • Uinstaliateur est responsable de faire une installation adequate! - Lire le manuel au complet avant de commencer. L'_tiquette portant le num_ro de modele se trouve sur le devant du four. Voir figure 1. La plaque de montage se trouve a I'arriere du four a micro-ondes.
  • Page 21 VOTRE sr:..CUR|TP:.. D 'ABORD • CET I_LECTROMI_NAGER DOlT l=TRE MIS A LA TERRE! - Dans le cas d'un court-circuit, la mise b,la terre r_duit le risque d'_lectrocution en fournissant un fil de fuite pour le courant _lectrique. Cet _lectrom_nager est muni d'un fil contenant un filet une broche de mise b, la terre. o Inserer la fiche dans une prise correctement installee et mise _ la terre.
  • Page 22 VOTRE sr=.cUR|TP=.D'ABORD ,, S'ASSURER D'AVOIR SUFFISAIVlMENT D'ESPACE ET DE SUPPORT - Monter le four sur un mur vertical et plat afin qu'il soit soutenu par lemur. Lemur dolt _tre construit avec des poutres de 2x4 po en bois au moins et du placopl&tre de 3/8 po (10 mm) o_ du pl&tre et des lattes. - VISSER AU MOINS UN des deux tire-fond soutenant le four dans une poutre verticale de 2 x 4 po.
  • Page 23 PiI CES, OUTiLS ET MATER|AUX ,, LES PI#CES SUIVANTES SONT FOURNIES AVEC LE FOUR REMARQUE : Selon les exigences d'&vacuation, certaines pibces pourraient ne pas _tre utilis_es Une bride d'attache de fil d'alimentation Registre/connecteur de conduit et une vis de couleur foncee (pour 6vacuation par le toit ou lemur)
  • Page 24 P|ECES, OUTiLS ET MATER|AUX LES OUTILS ET IVlATERIAUX SUIVANTS SONT REQUIS POUR UINSTALLATION Du carton ou autre mat&riau _pais pour couvrir le comptoir Ruban adh6sif transparent D&tecteur de poutre ou clou mince (pour fixer le gabarit & I'armoire) Scie & guichet (pour le trou du fil d'alimentation clans I'armoire) Scie sauteuse (pour d6couper...
  • Page 25 ETAPE 1 : PRI PARATiON DES CONNEX|ONS ELECTR|QUES AVERTISSEMENT i_VITER LES RISQUES D'i_LECTROCUTIONZ CET i_LECTROMENAGER DOlT f:TRE MIS A LA TERRE! 1. Placer une prise de courant mise _ la terre pour cet 61ectrom6nager dans I'armoire au-dessus du four tel que montr6 dans la Figure 4 Armoire (Detail) REMARQUE...
  • Page 26 F:TAPE 2 : PREPARAT|ON DU SYSTEME D'EVACUAT|ON REMARQUE : Les conduits n6cessaires pour 1'6vacuation vers I'ext6rieur ne sent pas fournis avec le four micro-ondes. Les raccords standards et leur 6quivalence de Iongueur sent montr6s dans Figure 9 _ la page AVERTISSEMENT : RISQUE D'INCENDIE...
  • Page 27 I TAPE 2 : PRIf:PARATiON DU SYSTE.ME D'E.VACUAT|ON RACCORDS STANDARD REMARQUE : Si les conduits existants sont fond, il faut utiliser un adaptateur rectangu/aire _ fond, avec une raflonge rectangulaire de 3 po (?5 install6e entre /'assemblage de registre I'adaptateur pour emp6cher le registre...
  • Page 28 ETAPE 3: PREPARAT|ON DU VENTiLATEUR D'EVACUAT|ON Le four & micro-ondes est fourni avec le ventilateur assemble pour 1'6vacuation par le toit. II faut faire ajustements pour 1'6vacuation par lemur ou dans la pi6ce (recirculation). AVERTISSEMENT RISQUE D'i_=LECTROCUTION! DISBRANCHER L'APPAREIL AVANT DE FAIRE DES TRAVAUX.
  • Page 29: Installation

    E.TAPE 3 : PREPARAT|ON DU VENT|LATEUR D'EVACUAT|ON INSTALLATION .A EVACUATION PAR LE ue arri6re Ventilateur MUR : 1. Retirer une vis de montage du ventilateur et une vis de montage de la la plaque du ventilateur, retirer la plaque du boTtier. plaque de ventilateur Voir la Figure 13.
  • Page 30 ETAPE 3: PREPARAT|ON DU VENT|LATEUR D'EVACUAT|ON -Vis de montage de la plaque de ventilateur Events #vents ventilateur Figure 17 (Option> Vis de montage du ventilateur Figure 18 INSTALLATION A EVACUATION DANS LA PIECE (Recirculation) 1. Retirer une vis de montage du ventilateur et une vis de la plaque...
  • Page 31 ETAPE 4 : PRE.PARATION DU MUR ET DE UARMOIRE SUPERIEURE POUR UINSTALLATION MESURER ET FIXER LES GABARITS AVEC DU RUBAN OU DES PLINAISES 1. Utiliser un niveau de macon et un ruban _ mesurer (m6tallique) pour trouver et marquer la ligne verticale centrale sur lemur tel qu'illustr6...
  • Page 32 ETAPE 4: PREPARATION DU MUR ET DE UARMOIRE SUPERIEURE POUR UINSTALLATION PER_AGE DES TROUS DANS LE MUR ET L'ARMOIRE SUPERIEURE AVERTiSSEMENT PRENDRE GARDE LORS DU PER(_AGE DES TROUS DANS LE MUR. Des fils _lectriques peuvent _tre dissirnul_s derriere la paroi du rnur et si la rn_che y touche, il y un risque d'_lectrocution, 1.
  • Page 33 ETAPE 5 : iNSTALLATiON DE LA PLAQUE DE MONTAGE SUR LE MUR ATTACHER LE FOUR A UNE POUTRE MURALE REMARQUE : Le four dolt #tre soutenu par au Trou de 3/16 po (5 ram) moins une poutre. pour les poutres Trou de 3/4 po (19 ram) 1.
  • Page 34 ETAPE 5 :iNSTALLATiON DE LA PLAQUE DE MONTAGE SUR LE MUR PRI_=PARATION DE L'OUVERTURE D'EVACUATION ET DE L'ADAPTATEU R/PLAQU E DE MONTAGE POUR L'i_=VACUATION PAR LE MUR. 1. Placer la plaque de montage centre lemur arri&re tel que d_crit au num_ro 1 de I'Etape 5 (page 15).
  • Page 35 ETAPE 6: FIXER LE FOUR AU MUR AVERTISSEMENT d'lallimentatio n II faut deux personnes pour soulever ce four _ micro-ondes. Une seule personne essayant de soulever le four pour le micro=ondes pourrait se blesser. fil d'alimentation 1. Soigneusement soulever le four A micro-ondes et I'accrocher sur les languettes de support (voir la Figure 26 _ la page 15) dans la bas de la plaque de montage.
  • Page 36 ETAPE 6: FIXER LE FOUR AU IVlUR 5. Installation pour I'_vacuation par le toit : Voir la Figure 32. Installer le conduit d'6vacuation dans I'armoire su- Registre p@ieure. Completer I'installation du syst_me d'_va- cuation par le toit selon la m_thode requise. Voir le num@o 2 de ,, PRE_PARATION DU SYSTIbME D'E_VACUATION ,, &...

This manual is also suitable for:

Hmv9303Hmv9306Hmv9307Hmv9305

Table of Contents