Download Print this page

Ace 3108651 User Manual

Motion sensing light

Advertisement

Available languages

Available languages

Quick Links

Motion Sensing
®
As an ENERGY STAR
determined that this product meets the ENERGY
®
STAR
guidelines for energy efficiency. This product
is ENERGY STAR
Watt bulbs.
Models 3108677/3108651/3108669
Note: Installation of this light control should be done only by those
with experience in 120 Volt household wiring. Some local codes
may require that a licensed electrician install the light control.
This light control automatically turns on lights when motion is
detected.
Two lamp holders are provided. The lamp holders are rated at 150
watts max. each.
1. Installation
Caution: Always turn the circuit breaker off when wiring
the fixture.
1. Remove the existing fixture.
2. The plastic hanger can be used to hold the fixture while wiring.
The small end of the plastic hanger can be threaded through the
hole in the center of the cover plate. The small end then goes into
one of the slots on the mounting strap.
3. Connect the light control as shown in Figure 1:
• Black sensor wire to the black (HOT) house wire.
• White sensor wire to the white (NEUTRAL) house wire.
Black to black
From House
House ground wire to green
ground screw on fixture.
Figure 1 - Wiring at Junction Box Plate
4. Attach the fixture to the mounting strap with the center mounting bolt.
Use a weatherproof sealant to seal the fixture to the junction box.
5. Install the protective lamp shields on the lamp holders by lining
up the groves on the narrow end of the shields with the dimples
in the lamp holders, push the shields into the lamp holders and
turn clockwise slightly.
6. Install the lamps in the lamp holders. Do not over tighten.
7. Adjustment lamp holders. The lamps should be at least 1 inch
away from the sensor.
Caution: Do not mount the sensor above or touching the lamps
(keep 1 inch or more from the lamps). The sensor bottom must be
facing down for best coverage and to avoid water damage and
electrical shock.
© 2003
Light
®
Partner, Heath
®
/Zenith has
®
compliant when used with 120
White to white
Push the rubber
plug firmly into
place
Note: For under-eave installation, rotate the sensor head 180° by
bending the sensor towards the clamp bracket. Rotate the sensor
bottom clockwise away from the bracket.
2. Aiming
The coverage area for the sensor is shown in Figure 2. The sensor
should be aimed so that the motion to be detected is in front of and
across the coverage area. The sensor should be aimed looking out at
a horizontal angle. To reduce false triggering, point the sensor away
from traffic areas, air conditioners, dryer vents, water pools, or
anything which may move or change temperature rapidly.
8 Ft.
Figure 2 - Coverage Angles
3. Testing
Turn the power back on at the circuit breaker. Turn the light switch
on.
Note: When first turned on wait about 1
to calibrate.
Put the TIME switch on the bottom of the sensor in the TEST position.
You can now walk in front of the unit and the lights will come on for
about 5 seconds. The TEST mode works both day and night.
Walk through the coverage area and point the sensor to obtain the
desired coverage area. Adjust sensitivity as needed.
4. Operation
For motion sensing, put the ON-TIME switch on the bottom of the
sensor in the 1, 5 or 10 minute position. When motion is detected, the
lights will come on the selected time. Note: The photocell keeps the
lights from turning on in daylight.
To keep lights on all night, flip the light switch off for 1 second then
back on. Turning the light switch off for 1 second then back on will
return the control to the motion sensing mode. At dawn, the control
will return to the motion sensing mode and shut off.

Specifications:

Total Lighting Wattage ...................... Up to 300 Watts Maximum
Lamp Holder Wattage ............... Up to 150 Watts Maximum each
Range ............................................................................ up to 70 ft.
Time Delay ...................................................... 1, 5, or 10 minutes
Caution: This product is to be used with a U.L. listed rain tight or
wet location suitable outlet box. Depending on the installation,
additional hardware may be required.
180°
70 Ft.
1
/
minutes for the circuitry
2
595-5751-02

Advertisement

loading

Summary of Contents for Ace 3108651

  • Page 1: Specifications

    Note: For under-eave installation, rotate the sensor head 180° by Motion Sensing bending the sensor towards the clamp bracket. Rotate the sensor ® bottom clockwise away from the bracket. Light 2. Aiming As an ENERGY STAR ® Partner, Heath ® /Zenith has The coverage area for the sensor is shown in Figure 2.
  • Page 2 Cuidado: El detector no debe estar sobre las lámparas ni debe Lámpara detectora tocarlas (mantenga 1 pulgada de distancia, o más, desde las lámpa- ® ras). La parte de abajo del detector debe mirar hacia abajo para del movimiento obtener una mejor cobertura y evitar un shock eléctrico y daños causado por el agua.

This manual is also suitable for:

31086693108677