Chapter 6 Permanent Parameters
FRPO Parameters
Note

Interface-dependent Parameters

6-2
The FRPO command changes the value of one parameter in permanent memory. A
separate command is required for each parameter change. The parameters, their
meanings, and the specifiable values are listed below.
In these tables, the Interface-dependent parameters affect the environment on the current
interface only. Any changes made to the parameters on one interface will not change
parameters on the other interfaces. To change a similar parameter on another interface,
first switch to that interface then issue the FRPO command.
The Interface-independent parameters affect all interfaces simultaneously. If the printing
system is shared with other users, remember that changes made to non-interface-
dependent parameters can affect users on other interfaces as well.
Certain parameters are available only when the printing system is installed with the rele-
vant option equipment.
Table 6.1. Interface-dependent Parameters (Sheet 1 of 3)
Environment
Parameter
a
Top margin
A1
A2
a
Left margin
A3
A4
a
Page length
A5
A6
a
Page width
A7
A8
a
Page orientation
C1
a
Default font No.
C5
C2
C3
Operation panel
C6
settings saving
c
PCL font range
C8
a
KC-GL options
G0
a
KC-GL pen width
G1 through G8 0 to 99 dot
Interface release time-
J2
out
Value
Integer value in inches
Fraction value in 1/100 inches
Integer value in inches
Fraction value in 1/100 inches
Integer value in inches
Fraction value in 1/100 inches
Integer value in inches
Fraction value in 1/100 inches
0: Portrait, 1: Landscape
First two digits of power-up font
Middle two digits of power-up font
Last two digits of power-up font
0:
Not saved at power-off
1:
Saved at power-off
0:
Includes proportional bitmap fonts
1:
Excludes proportional bitmap fonts in range
0:
Mode A; formfeed to SP0
1:
Mode B; formfeed to SP0
2:
Mode A; no formfeed to SP0
3:
Mode B; no formfeed to SP0
4:
Fixed mode A; formfeed
5:
Fixed mode B; formfeed
6:
Fixed mode A; no formfeed
7:
Fixed mode B; no formfeed
8:
Mode A; formfeed
9:
Mode B; formfeed
10: Mode A; no formfeed
11: Mode B; no formfeed
12: Fixed mode A; formfeed
13: Fixed mode B; formfeed
14: Fixed mode A; no formfeed
15: Fixed mode B; no formfeed
0 to 99 in units of 5 seconds
Factory setting
0
0
0
0
b
13 (17)
b
61 (30)
b
13 (17)
b
61 (30)
0
00
00
00
1
0
0
01/02/03/04/
05/06/07/08
6