7.2.16. Setting the KBD PCB, MDC Modem and LCD Cable/MIC Frame
1. Connect the three Cables to the three Connectors
(CN930, CN950, CN952) on the KBD PCB.
2. Fix the KBD PCB using the two Screws<H>. No1, No2
3. Connect the Cable to the Connector (J2) on the MDC
Modem.
4. Attach the Sheet to the MDC Modem.
5. Fix the MDC Modem using the two Screws<I>. No3, No4
6. Attach the LCD Conductive Sheet and the Gasket to the
LCD Cable/MIC Frame.
7. Set the LCD Cable/MIC Frame to the Top Cabinet.
Note:
Tighten the Screws in the numbered order (No1 to No4).
Screws <H>: DFHE5025XA
Screws <I>: DFHE5025XA
n Attaching the Sheet to the MDC Modem
1. Connect the Cable to the Connector (J2) on the MDC Modem.
2. Attach the Sheet to the MDC Modem.
Safety Working
MDC Modem
Connector (J2)
Cable
View "A"
View "A"
5~7mm
Sheet
3~4mm
Connector CN950
(front side)
<H>
Connector CN952
:No1
<H>
(reverse side)
:No2
Connector CN930
(reverse side)
KBD PCB
Top Cabinet
to Connector
(CN930)
MDC Modem
Connector (J2)
Cable
7-34
Connector J1
(reverse side)
<I>
<I>
:No3
Sheet
:No4
MDC
Modem
Connector J2
Gasket
(reverse side)
to Connector
(CN950)
to Connector
(CN952)
LCD Conductive
Sheet
LCD Cable/
MIC Frame
to Connector
(J2)
Place the Cable not to
pass through this range.
Sheet