Lenovo 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp Hardware Maintenance Manual page 64

Hardware maintenance manual
Hide thumbs Also See for 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp:
Table of Contents

Advertisement

Diagnostic Error Code
086-197-XXX Mouse Port interface test warning
086-198-XXX Mouse Port interface test aborted
086-199-XXX Mouse Port interface test failed, cause
unknown
089-000-XXX Microprocessor Test Passed
089-XXX-XXX Microprocessor failure
089-195-XXX Microprocessor Test aborted by user
089-196-XXX Microprocessor test halt, error threshold
exceeded
089-197-XXX Microprocessor test warning
089-198-XXX Microprocessor test aborted
089-199-XXX Microprocessor test failed, cause unknown
170-000-XXX Voltage Sensor(s) Test Passed
170-0XX-XXX Voltage Sensor(s) failure
170-195-XXX Voltage Sensor(s) Test aborted by user
58
ThinkCentre Hardware Maintenance Manual
FRU/Action
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 521
3. Go to "Undetermined problems" on page 65
1. See "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 521
3. Replace component under function test
No action
1. Microprocessor(s)
2. System board
Information only Restart the test, if necessary
1. Press F3 to review the log file
2. Restart the test to reset the log file
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. Flash the system. See "Flash update procedures"
on page 521
2. Go to "Undetermined problems" on page 65
1. See "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 521
3. Replace component under function test
No action
1. Flash system
2. System board
Information only Restart the test, if necessary