To avoid these security messages:
Open Internet Explorer 6.0.
1.
Select Tools>Internet Options.
2.
Select the Security tab.
3.
Click Local intranet.
4.
Manually set the servers to the Local intranet zone by entering:
5.
http://<servername or IP address>:2301
https://<servername or IP address>:2381
Static LUN balancing
The Smart Array Multipath software and Microsoft operating system support static LUN balancing. The
movement of drives to specific paths can be done two ways:
Locally with a DME
Remotely with the Smart Array Multipath found on the Smart Array Multipath Software CD
To balance LUNs with the DME:
From the desktop, right-click My Computer.
1.
Click Manage. The Device Manager window opens.
2.
Click SCSI and RAID Controllers.
3.
Right-click one of the array controller icons and click Properties.
4.
When the Properties window opens, click the Redundancy Configuration tab.
5.
From the Redundancy Configuration tab, the administrator can view the following controller
information:
Name
Slot number
Status
Slot number of redundant controller
Controller tree
In the controller tree, right-click one of the logical volumes and then click Switch Path. The system
6.
moves the logical volume to the other path.
To manage your redundant configuration:
First-time users must install the software. Install the ProLiant Storage Manager software and Smart
1.
Array Multipath Manager software
Browse to the System Management Homepage by entering:
2.
https:\\<name of server>:2381
IMPORTANT: If you encounter numerous security messages on a Microsoft® Windows® Server 2003
platform, review the Microsoft browser security settings (on page 11).
To accept the security certificate, click Yes. The system may prompt for the administrator password
3.
established during the original software installation. The System Management Homepage opens.
Click the Home tab.
4.
Select ProLiant Storage Manager. A new window opens.
5.
Click the appropriate controller on the Device View tab.
6.
Click Multipath Management. The Multipath Management and Configuration screen displays.
7.
("Multipath installation for
Installation and operation in Microsoft environments 12
Microsoft" on page 11).
Need help?
Do you have a question about the StorageWorks 500 - G2 Modular Smart Array and is the answer not in the manual?
Questions and answers