Brother LK3-B434E MKII Instruction Manual page 59

Electronic lockstitch pattern tacker
Hide thumbs Also See for LK3-B434E MKII:
Table of Contents

Advertisement

13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
Memory switches 10 - 1F
Switch
memo-10
-
memo-11
Pneumatic wiper can be used. (Pneumatic wiper is available by special
memo-12
order.)
The inner clamping device moves forward at the 1/4-way mark and returns
memo-13
at the 3/4-way mark for the pattern being sewn.
memo-14
Solenoid wiper can be used.
When using the inner clamping device, shunting to prevent interference
memo-15
between the inner clamping device and the needle is not carried out after
the sewing end.
Needle cooler output is enabled. (Needle cooler is available by special
memo-16
order.)
memo-17
Thread take-up device is not operated at the sewing end.
memo-18
Thread take-up device operates one stitch before the sewing end.
memo-19
For solenoid specifications, presser position errors are not detected.
memo-1A
Needle up stop position errors are not detected.
Presser can be moved up and down before the home position is detected.
memo-1b
(Normally the presser cannot be moved up and down until after the home
position has been detected.)
memo-1c
For pneumatic specifications, the air pressure detection switch is enabled.
memo-1d
(The air pressure sensor is a special-order option.)
memo-1E
Errors can be reset using the EMERGENCY STOP switch.
memo-1F
Thread is not trimmed when an emergency stop occurs during sewing.
Memory switches 20 - 2F
Switch
Machine head from previous B430E series is used. (Only the operation
memo-20
panel and box are Mark II.)
Rotating-type thread breakage detector operates. (Device is available by
memo-21
special order.)
During thread breakage detection, sensitivity is decreased from 8 to 14
memo-22
stitches at the sewing start. (Sensitivity during sewing is three stitches.)
When DIP switch A-8 is simultaneously ON, setting values changed using
memo-23
the operation panel are ignored.
The lower thread sensor operates. (The lower thread sensor is a special-
memo-24
order option.)
memo-25
-
memo-2F
53
Motion when set to ON
Motion when set to ON
LK3-B434E Mark II
Initial value
Solenoid Pneumatic
--
--
--
--
--
--
--
ON
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Initial value
Solenoid Pneumatic
--
--
--
--
--
--
--
--
--
--
--
--

Hide quick links: