Mouse - IBM PC 300 Maintenance Service Manual

For micro tower & desktop models
Hide thumbs Also See for PC 300:
Table of Contents

Advertisement

Mouse

NOTE: A sticking key button can cause the mouse to operate incorrectly. If you suspect this, go to "Keyboard" on page 75.
001 - START
Make sure that the mouse ball turns freely.
Make sure that the mouse plug connects properly.
002 -
Power off the system unit.
Insert the diagnostics diskette into the diskette drive.
Power on the system unit.
Select Interactive Tests menu, then execute Mouse test.
003 - DO YOU SEE THE MOUSE CURSOR IN THE DIAGNOSTICS PROGRAM? (YES, READ AHEAD. NO, GO TO
STEP 011)
Test right (left) button and check if right (left) button works.
004 - DOES THE MOUSE BUTTON WORK? (YES, READ AHEAD. NO, GO TO STEP 007)
Test mouse cursor movement.
005 - DOES THE MOUSE MOVE SMOOTHLY AND KEEP X AND Y COORDINATES CHANGED? (YES, READ AHEAD.
NO, GO TO STEP 006)
Mouse is functioning normally.
End.
006 -
Power off the system unit.
Open mouse bottom cover and clean track ball.
Go to step 002.
007
Power off the system unit.
Check the mouse plug.
008 - ARE THERE ANY BROKEN PINS IN THE MOUSE PLUG? (YES, GO TO STEP 010. NO, READ AHEAD.)
Try with a known good mouse.
009 - DO THE ERROR SYMPTOMS STILL REMAIN? (YES, READ AHEAD. NO, GO TO STEP 010.)
Replace the system board.
End
010 -
Replace the mouse.
End.
011 -
Exit diagnostics program.
Make sure that the mouse driver is properly installed.
Go to step 002.