PLV-HD2000 Expand Serial Command Functional Specifications
9.8.4. CR_LAMPSTS Command
Command
CR_LAMPSTS" [CR]
Details
Get the information of Lamp status
Acceptable
Response
Unacceptable
9.8.5. CR_INFLAMP Command
Command
"CR_INFLAMP" [CR]
Details
Get Lamp mode switching status
Acceptable
Response
Unacceptable
9.8.6. CR_PROJH Command
Command
"CR_PROJH" [CR]
Details
Get total running time of Projector by hour (h)
Acceptable
Response
Unacceptable
9.8.7. CR_HMLAMP Command
Command
"CR_HMLAMP" [CR]
Details
Get total number of lamps
Acceptable
Response
Unacceptable
"000_%1" [CR]
"4****"
The first character indicates the model is 4-lamp system.
The following characters indicates the lamp status as below:
"I" ----------- Lamp is ON
%1
"O" ---------- Lamp is OFF
"X" ---------- Lamp Failure
e.g.
"4IOXI" ----- 4-lamp system, Lamps 1&.4 are ON. Lamp 2 is OFF,
and Lamp 3 is failed.
"Error Code" [CR]
"000_%1" [CR]
"NML" ---------- Normal (not in the lamp switching process)
%1
"CNG" ---------- preparing for switching lamps
"Error Code" [CR]
"000_%1" 「CR」
%1
"0000000" – "0065535"
"Error Code" [CR]
"000_%1" [CR]
%1
"001" – " 004"
"Error Code" [CR]
47/56