PLC-XU305/355 Expand Serial Command Functional Specifications
8.7.7
CF_HSCALE Command
Command
"CF_HSCALE_%1"[CR]
"032" --------- +32
"031" --------- +31
ÿ
"002" --------- +2
"001" --------- +1
"000" --------- +0
%1
"-01" ---------- -1
"-02" ---------- -2
ÿ
"-31" ---------- -31
"-32" ---------- -32
"UP" ---------- Horizontal Scale setting value + 1
"DN" ---------- Horizontal Scale setting value - 1
Set Horizontal Scale
This command is available in normal Power ON status.
Note1) When Screen setting is not in Custom mode, projector changes image
Details
mode into Custom by receiving this command.
Note2) When there is no signal detected, projector returns 101 and the command
does not excute.
Acceptable
Response
Unacceptable
8.7.8
CF_HPOS Command
Command
"CF_HPOS_%1"[CR]
"015" --------- +15
"014" --------- +14
ÿ
"002" --------- +2
"001" --------- +1
"000" --------- +0
%1
"-01" ---------- -1
"-02" ---------- -2
ÿ
"-14" ---------- -14
"-15" ---------- -15
"UP" ---------- Horizontal Position setting value + 1
"DN" ---------- Horizontal Position setting value - 1
Set Horizontal Position
This command is available in normal Power ON status.
Note1) When Screen setting is not in Custom mode, projector changes image
Details
mode into Custom by receiving this command.
Note2) When there is no signal detected, projector returns 101 and the command
does not excute.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
30/68