■ Removing and Reinstalling the Pickup Roller
1.
Open the upper unit smoothly.
Upper Unit" on p. 5-3.)
2.
Open the roller cover.
3.
Open the roller holder.
Hint
The roller holder returns to its original position when released.
4.
Remove the pickup roller, and set a clean pickup
roller or a replacement pickup roller.
(See "Opening the
5-10
IMPORTANT
Install the Pickup Roller so that the side with the gear is on the
left.
Gear
5.
Close the roller cover. Make sure to hear a latching
sound and that it is securely returned to its original
position.
IMPORTANT
Failure to firmly close the roller holder and roller cover may
cause a feed error. Always be sure to check that the roller holder
and roller cover are closed.
6.
Smoothly close the upper unit.
Upper Unit" on p. 5-3.)
Chapter 5 Maintenance
(See "Closing the